Deutz-Fahr 572 – ECM: Exhaust Gas Recirculation 1 Valve Position - Voltage Below Normal Value or Short Circuit to Ground
Issue description
The Engine Control Module (ECM) has detected an abnormally low voltage signal from the Exhaust Gas Recirculation (EGR) valve's position sensor, or the circuit is shorted to ground. The EGR position sensor operates on a 5-volt reference signal; a voltage reading near zero indicates a signal wire short-circuit or a failed sensor. This fault causes the ECM to disable the EGR valve's operation.
Applies to these machines
22 machines- 4070E
- 4080E
- 4090E
- 4100E
- 5080D
- 5090D
- 5100G
- 5120G
- 5115G TB
- Serie 5 D
- Serie 5 DF
- Serie 5 G
- 6120
- 6130
- 6140 Agrotron
- Agroplus F 70
- Agroplus 80.4F
- 5120
- Agrotron K120
- 6120 TTV
- 6130 TTV
- 6140 TTV
Check the cause
Verify ECM calibration to ensure the software is up to date, as updates can sometimes resolve fault code issues
Inspect the wiring harness and connectors near the EGR valve for chafing, corrosion, heat damage, or loose pins. Perform a wiggle test on the connector while monitoring sensor voltage
Check for a stable 5-volt reference supply from the ECM to the EGR position sensor with the ignition on
Test the signal wire by back-probing the connector with the ignition on. Normal closed-valve voltage is 0.7 to 1.5 volts; a reading near zero indicates a short to ground
Perform an EGR actuator test using Deutz SerDia diagnostic software to observe valve movement and voltage changes (voltage should increase to 3.5-3.9V when fully open)
Repair steps
Safety First
Ensure the engine is cool to the touch and disconnect the negative battery terminal to prevent electrical shorts.
Drain Coolant
If the EGR valve is coolant-fed, partially drain the cooling system to a level below the valve to minimize coolant loss.
Disconnect Electrical and Mechanical Connections
Unplug the electrical connector from the EGR valve. Disconnect any coolant or vacuum hoses connected to the valve. Loosen and remove the bolts or clamps securing the exhaust pipes to the valve (these may be seized and require penetrating oil).
Remove the Old Valve
Unbolt the EGR valve from its mounting point on the engine or intake manifold. The valve may be stuck due to carbon buildup and may require gentle prying to remove.
Clean Mating Surfaces
Thoroughly clean the mounting surfaces of the intake manifold and any exhaust connections to remove all traces of the old gasket and carbon deposits to ensure a proper seal.
Install the New Valve
Place the new gasket on the cleaned mounting surface. Position the new EGR valve and hand-tighten the mounting bolts to prevent cross-threading. Using a torque wrench, tighten the bolts to the manufacturer's specified torque in a crisscross pattern.
Reconnect and Refill
Reconnect the exhaust pipes, coolant/vacuum hoses, and the electrical connector. Refill the cooling system with the appropriate coolant and reconnect the negative battery terminal.
Clear Codes and Perform Relearn
Use a diagnostic tool like Deutz SerDia to clear the fault code from the ECM's memory. Perform an EGR actuator reset or calibration procedure with the diagnostic tool so the ECM learns the position of the new valve.
Test Drive
Conduct a test drive to ensure the Check Engine light does not return and that the engine is operating smoothly.
Parts you might need
(9)- EGR Valve0.019.7395.0/20
OEM part number
EGR Valve
04120822OEM part number
EGR Valve
DTZ04102108OEM part number
EGR Valve
04516168For Deutz 6.1 engines
EGR Valve
04516701For Deutz 6.1 engines
- EGR Cooler Shuttle/Reed Valve04257888
Potential failure point in EGR cooler
- EGR Cooler Shuttle/Reed Valve04265310
Potential failure point in EGR cooler
EGR Cooler Shuttle/Reed Valve
04515377Potential failure point in EGR cooler
EGR Cooler Shuttle/Reed Valve
04125434Potential failure point in EGR cooler
Get help to fix this fault by requesting a quote