594

Deutz-Fahr 594 – ECU: Fuel Metering Unit Short to Battery

Issue description

The Engine Control Unit (ECU) has detected a short circuit to the positive side of the battery in the fuel metering unit's high-side electrical circuit (also known as the M-Prop valve or Fuel Control Actuator). This indicates that the electrical wire leading from the ECU to the metering unit is likely making contact with a wire carrying positive battery voltage, causing abnormally high current flow. This condition leads to a loss of control over fuel pressure, affecting the proper operation of fuel system components and potentially causing electrical system malfunctions and engine performance issues.

Applies to these machines

  • TCD 2.9 L4
  • TD 2.9 L4
  • TCD 3.6 L4
  • TCD 4.1 L4
  • Engines from 4 to 16 liters with EDC17CV5x controllers
  • 1011 Series
  • 2011 Series

Check the cause

  1. Visually inspect the wiring harness leading to the fuel metering unit for chafing, melting, or corrosion, paying close attention to areas where the harness contacts the engine block.

  2. Disconnect and inspect the electrical connector at the fuel metering unit for corrosion, moisture, or pushed-out pins (the original connector is prone to vibration failure).

  3. Using a multimeter, check for a short to positive voltage on the signal wire to the fuel metering unit. With the ignition on and the component disconnected, there should be no battery voltage present on the signal wire from the ECU.

  4. If the wiring and connectors are in good condition, test the fuel metering unit component itself using a diagnostic tool like Deutz SerDia.

Repair steps

  1. Prepare machine and depressurize

    Turn off the engine, allow it to cool, and disconnect the negative battery terminal. Follow the manufacturer's procedure to depressurize the high-pressure common rail fuel system.

  2. Access the fuel metering unit

    Locate the fuel metering unit on the high-pressure fuel pump. Access may require the removal of other components.

  3. Repair wiring or connector

    If diagnostic checks revealed a damaged wiring harness or connector, repair the affected wires or install a replacement pigtail kit for the faulty plug.

  4. Replace fuel metering unit

    If the metering unit is faulty, disconnect its electrical connector and fuel lines. Remove the securing bolts from the high-pressure pump, install the new unit with new gaskets/seals, torque to manufacturer specifications, and reconnect the lines.

  5. Bleed fuel system

    Use the manual priming pump to bleed any air that may have entered the fuel system during component replacement.

  6. Clear codes and test

    Reconnect the battery, clear the fault code from the ECU memory using a diagnostic tool, start the engine, check for fuel leaks, and verify the fault does not return.

Parts you might need

(4)
  • Fuel Metering Unit

    04272612

    For Deutz 1011 series engines (replaces 04270733)

  • For select Deutz diesel engines

  • For Deutz TCD 3.6 L4 (2011-2019)

  • M-Prop/Metering Unit Repair Kit

    For Deutz 2.9 and 3.6 engines; includes metering unit control valve, new harness connector, and gasket

Get help to fix this fault by requesting a quote