597
Deutz-Fahr 597: Fuel Metering Unit - Mass Short Circuit Minus Side
Issue description
The fault code indicates a mass short circuit on the minus side of the fuel metering unit within the fuel system. This issue may affect the proper operation of the fuel metering unit.
Check the cause
The wiring and connections related to the fuel metering unit
The integrity of the minus side circuit of the fuel metering unit
The component identified by this code
Repair steps
Inspect
Inspect the wiring and connections associated with the fuel metering unit for damage, wear, or loose contacts.
Test
Test the minus side circuit of the fuel metering unit for continuity and proper insulation.
Replace
If damage or fault is found, replace the affected circuit or the component identified by this code.
Parts you might need
(0)Get help to fix this fault by requesting a quote