Deutz-Fahr 655 – ECU: Short Circuit in Injector 5
Issue description
A short circuit has been detected in injector 5, indicating an electrical malfunction within its circuit such as a short to battery, short to ground, or a cable break. The Engine Control Unit (ECU) detects an abnormal current reading (too high or too low) and stops firing the injector to prevent damage, which causes the engine to run on one fewer cylinder.
Applies to these machines
3 machines- Deutz-Fahr Agrotron M620
- Deutz-Fahr Agrotron M640
- Deutz-Fahr 6095 HTS Combine Harvesters
Check the cause
Visually inspect the wiring harness leading to injector 5 for chafing, melting, or corrosion.
Check that the electrical connector at the injector is securely fastened and free of contamination or corrosion.
Disconnect the harness from injector 5 and examine the connector terminals and the injector pins for damage, corrosion, or pins that may have pushed back into the connector housing.
With the injector disconnected, use a multimeter set to Ohms (Ω) to measure the resistance across the two terminals of the injector itself. Compare this reading to the manufacturer's specification. A reading of zero or near-zero indicates a short circuit, while an infinite reading (open loop) indicates a break in the coil. Also, compare the reading to the other injectors; a significant deviation on injector 5 points to a faulty injector.
With the injector and the ECU disconnected, use a multimeter to check for continuity on both wires running between the ECU connector and the injector 5 connector to verify there are no breaks. Then, check for a short circuit by testing for continuity between each of those two wires and the chassis ground, and then to a battery positive source. There should be no continuity in these tests.
Repair steps
Clear Fault Codes
After performing initial visual checks, clear the fault codes and run the engine to see if the code returns immediately. If it does, a 'hard' fault is present.
Perform Diagnostic Tests
Follow the diagnostic checks listed above, starting with the simplest (visual inspection) and progressing to electrical measurements.
Isolate the Fault - Wiring Harness
If the wiring harness is found to be damaged, repair or replace it.
Isolate the Fault - ECU
If the wiring and the injector both test good, the issue may lie with the Engine Control Unit (ECU) itself, which is the least common cause.
Replace the Injector (if necessary)
If the injector's internal resistance is out of specification, the injector is faulty and must be replaced. Ensure the area around the injector is clean to prevent contamination of the fuel system. Disconnect the fuel lines and electrical connector from the faulty injector. Remove the injector hold-down clamp and carefully extract the injector from the cylinder head. Install the new injector with new seals and O-rings. Torque the hold-down clamp to the manufacturer's specified value. Reconnect the fuel lines and electrical connector.
Final Verification
After reassembly, clear any stored fault codes from the ECU. Start the engine and check for fuel leaks and verify that the fault code does not reappear.
Parts you might need
(4)Fuel Injector
04290986Fits Deutz TCD 2013 L06 2V engines
- Fuel Injector04902525
Bosch equivalent 0445120074. Fits Deutz TCD 2013 L04 and L06 4V engines
Fuel Injector
04902825Alternate part number 04902255. Fits Deutz TCD 2013 L04 4V and TCD 2013 L06 4V engines
Fuel Injector
04289311Fits Deutz TCD 2013 L4 2V engines
Get help to fix this fault by requesting a quote