656
Deutz-Fahr 656: Cable Break in Injector 6
Issue description
A fault has been detected in the cable associated with injector 6. This fault indicates a break in the wiring, which may prevent proper operation of the component.
Check the cause
Cable associated with injector 6
Connections at injector 6
Cable routing for injector 6
Repair steps
Inspect
Visually inspect the cable associated with injector 6 for any signs of damage, wear, or breakage.
Test
Use a multimeter to test the continuity of the cable associated with injector 6.
Replace
If a break is confirmed, replace the cable associated with injector 6 with a new one.
Parts you might need