Deutz-Fahr 78: Battery Short Circuit at the Water Pump Control
Issue description
A short circuit has been detected in the battery circuit related to the water pump control. This fault may affect the proper operation of the water pump and could lead to electrical system instability.
Check the cause
The wiring and connections associated with the water pump control
The battery and its connections to the water pump control circuit
The water pump control itself for signs of damage or shorting
Repair steps
Inspect
Inspect the wiring and connections associated with the water pump control for damage, wear, or signs of shorting.
Test
Test the battery and its connections to the water pump control circuit for proper voltage and continuity.
Examine
Examine the water pump control for physical damage or signs of internal shorting.
Parts you might need
(0)Get help to fix this fault by requesting a quote