Deutz-Fahr 793 – ECM: AGR-Venturi Sensor Plausibility Check Error
Issue description
The Engine Control Module (ECM) has detected an implausible signal from the EGR differential pressure sensor (AGR-Venturi sensor). This indicates that the sensor's readings are erratic, intermittent, or outside the expected range, failing to correlate correctly with other engine parameters. As a result, the ECM disables the EGR valve's operation to prevent incorrect emission levels and potential engine performance issues.
Applies to these machines
4 machines- TCD 3.6
- TCD 4.1
- TCD 6.1
- TCD 7.8
Check the cause
Verify the ECM calibration is correct and check for any available software updates to resolve potential fault logic issues
Check for any other active fault codes related to the EGR valve position or other EGR system sensors
Visually inspect the EGR differential pressure sensor, wiring harness, and connectors for visible damage, corrosion, loose connections, or moisture intrusion
Inspect the two small rubber or silicone hoses connecting the sensor to the EGR venturi pipe for cracks, melting, kinks, or blockages
Repair steps
Clean sensor ports and hoses
Disconnect the hoses from the sensor and the EGR pipe. Carefully clean the inside of the hoses and thoroughly clean the metal ports on the EGR pipe. Blockage of these passages by soot and carbon buildup is the most common cause of this fault.
Perform electrical testing
With the key on and engine off, back-probe the sensor's electrical connector. Verify a 5-volt reference supply from the ECM and a good ground connection. Measure the signal wire voltage, which should be between 0.55 and 0.83 volts. If voltages are incorrect, check the harness for continuity and shorts between the pins.
Test sensor functionality
If wiring and ports are good, monitor the EGR differential pressure reading with a diagnostic tool while the engine is running. Command the EGR valve to open and close to see if the reading responds. Alternatively, use a handheld vacuum/pressure pump on the sensor's intake port to verify the signal voltage changes in response to pressure.
Replace components or clear system blockages
If the sensor fails the electrical or functional tests, replace it. If the sensor and its pathways are functioning properly but no flow is detected, inspect for a stuck EGR valve or a blockage in the main EGR cooler or pipes.
Parts you might need
(7)Also known as AGR-Venturi Sensor or Delta P Sensor. Fits Deutz TCD 3.6, 4.1, 6.1, and 7.8 engines. Verify with machine serial number.
EGR Valve
0412-0024Example part for TCD 2.9/3.6 L4 engines.
EGR Valve
0412-0424Example part for TCD 2.9/3.6 L4 engines.
- EGR Shuttle/Reed Valve04257888
For various Deutz TD/TCD engines.
- EGR Shuttle/Reed Valve04265310
For various Deutz TD/TCD engines.
EGR Shuttle/Reed Valve
04515377For various Deutz TD/TCD engines.
EGR Shuttle/Reed Valve
04125434For various Deutz TD/TCD engines.
Get help to fix this fault by requesting a quote