Skip to main content
793

Deutz-Fahr 793 – ECM: EGR Delta Pressure Sensor Implausible Signal

Issue description

The Engine Control Module (ECM) has detected that the signal from the Exhaust Gas Recirculation (EGR) delta pressure sensor is illogical or inconsistent with expected values for the current engine operating conditions. The sensor monitors the pressure difference across the EGR venturi to calculate exhaust gas flow. An implausible reading indicates a potential sensor failure, wiring issue, or physical blockage in the EGR passages.

Applies to these machines

  • Agrotron

Check the cause

  1. Visually inspect the EGR delta pressure sensor, wiring harness, and connectors for physical damage, corrosion, or loose connections.

  2. Inspect the hoses running to the sensor for cracks, brittleness, or blockages.

  3. Check the metal ports on the EGR pipe where the hoses connect for soot and carbon buildup (clogged ports are a common cause).

  4. Perform an electrical 'wiggle' test on the sensor wiring harness with the engine running and a diagnostic tool connected; erratic pressure readings indicate a broken wire or poor connection.

  5. Verify the sensor is receiving a stable supply voltage from the ECM (typically around 5 volts) with the key on and engine off.

  6. Check the sensor signal voltage with a multimeter (expected range is 0.55 to 0.83 volts at key-on, engine-off). Readings outside this range often point to a faulty sensor.

  7. Check for other active or stored fault codes related to the EGR or after-treatment system (such as SPN 411 FMI 3 or 4).

Repair steps

  1. Ensure safety and prep machine

    Turn the vehicle off and allow the engine and exhaust components to cool completely. Disconnect the battery to prevent electrical issues.

  2. Clean EGR passages

    If a blockage was found during inspection, disconnect the hoses from the EGR pipe and thoroughly clean the ports using a small pick or drill bit to remove all carbon buildup. Clean the hoses as well, ensuring they are clear.

  3. Remove faulty sensor

    Carefully disconnect the electrical connector from the EGR delta pressure sensor. Unbolt the sensor from its mounting bracket.

  4. Install new sensor

    Mount the new sensor and securely tighten the bolts. Reconnect the electrical connector and ensure it clicks into place. Re-attach the pressure-sensing hoses.

  5. Clear fault codes

    Reconnect the battery. Using a diagnostic tool, clear the active and stored fault codes from the ECM.

  6. Perform system verification

    Start the engine and allow it to warm up to operating temperature. Perform a service regeneration or an 'EGR Delta Pressure Sensor Recalibration' with a diagnostic tool to ensure the system recognizes the new component. Verify the fault code does not reappear.