84

Deutz-Fahr 84: CAN-Bus 0: Bus Off-Status

Issue description

The CAN-Bus 0 (Customer-CAN) has detected a Bus Off status, indicating a communication failure on the CAN network. This typically occurs when a node is unable to communicate properly, often at a baud rate of 250kbaud.

Check the cause

  1. The integrity of the CAN-Bus 0 wiring and connections

  2. The functionality of the CAN-Bus 0 module or controller

  3. The presence of any short circuits or open circuits on the CAN-Bus 0 line

Repair steps

  1. Inspect

    Check the physical connections and wiring of the CAN-Bus 0 for damage, corrosion, or loose connections.

  2. Test

    Use a diagnostic tool to verify the communication status of the CAN-Bus 0 and identify any nodes that may be causing the issue.

  3. Replace

    If a faulty component is identified, replace the affected module or controller on the CAN-Bus 0.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote