Skip to main content
893

Deutz-Fahr 893 – ECM: SCR DEF Pump Pressure Build-Up Fault

Issue description

The engine's control system has detected a problem with the pressure of the AdBlue/Diesel Exhaust Fluid (DEF) within the Selective Catalytic Reduction (SCR) after-treatment system. The system indicates that pressure is not being built up properly by the feed pump, meaning it cannot build or maintain the target pressure required for correct emissions operation. This may affect the proper operation of the component or system associated with the feed pump.

Applies to these machines

  • TCD 3.6

Check the cause

  1. Verify DEF/AdBlue level and quality using a refractometer to ensure it meets the ISO 22241 standard (poor quality or old fluid causes crystallization).

  2. Visually inspect the entire AdBlue system (tank, pump module, fluid lines, injector) for leaks or white, crusty crystal deposits.

  3. Check the AdBlue injector, lines, and filters for blockages caused by crystallized urea or contaminants.

  4. Listen to the AdBlue pump when the ignition is turned on to ensure it is priming properly (unusual noises or silence indicate failure).

  5. Inspect electrical wiring and connectors to the AdBlue pump, pressure sensor, and controller for damage, corrosion, or loose connections.

Repair steps

  1. Read fault codes

    Use a compatible diagnostic tool, such as the Deutz SerDia tool, to confirm fault 893 and check for any other active SCR-related codes (e.g., 894, 897, 898).

  2. Address preliminary issues

    If issues with DEF quality, leaks, or blockages were found, drain the tank, clean components with deionized water, and replace filters.

  3. Test pump pressure

    Test the AdBlue pump's pressure output against manufacturer specifications using specialized tools. If it fails to produce adequate pressure, the pump is likely faulty and must be replaced.

  4. Test pressure sensor

    If the pump pressure is verified to be correct, test the pressure sensor and its wiring, as a faulty sensor can send incorrect readings to the ECU triggering the pressure fault.

  5. Inspect dosing valve/injector

    Remove and inspect the AdBlue dosing valve to ensure it is not stuck open, stuck closed, blocked, or damaged.

  6. Replace faulty components

    Replace the AdBlue pump, pressure sensor, or dosing valve as dictated by the diagnostic test results.

  7. Clear faults and test system

    Use the diagnostic tool to clear the fault codes. Perform a system function test or forced regeneration to verify the repair was successful and the code does not return.

Parts you might need

(2)
  • AdBlue / DEF Pump (Supply Module)

    04609002

    Alternative part numbers include 04603859, 04609000, 04600620, 0444042019. Often manufactured by Bosch. Verify against engine serial number.

  • Alternative part numbers include 4213368, 04189466, 1183692. Ensure this is the specific pressure sensor for the SCR system, not oil or air.

Get help to fix this fault by requesting a quote

Browse other Deutz-Fahr codes