Deutz-Fahr 916 – ECM: DEF Supply Module Temperature Signal Implausible
Issue description
Associated with SPN 523721 and FMI 2. The system has detected an implausible signal from the temperature sensor located in the AdBlue (DEF) supply module. This indicates that the temperature reading is unrealistic or illogical when compared to other operational data the engine's control system is receiving. This is a plausibility error regarding the accuracy or integrity of the temperature reading, rather than a standard open or short circuit fault.
Applies to these machines
3 machines- TCD 4.1 L4
- TCD 6.1 L6
- TCD 7.8 L6
Check the cause
Scan for any other active or stored fault codes related to the SCR system (e.g., DEF tank heater, DEF quality sensor, or communication errors) that could provide additional clues.
Visually inspect the DEF supply module's temperature sensor and electrical connector for corrosion (white or greenish deposits), moisture ingress, or physical damage.
Check the wiring harness between the DEF supply module temperature sensor and the engine ECU for continuity, short circuits to power or ground, and areas subject to rubbing or excessive heat.
Disconnect the sensor and measure its resistance with a multimeter. A generic reference for DEF temperature sensors is approximately 942 ohms at 0°C (32°F) and 330 ohms at 25°C (77°F).
Repair steps
Address related faults
Diagnose and repair any other SCR-related fault codes first, as they may be the root cause of the implausible temperature reading.
Repair wiring harness
If diagnostic checks reveal corrosion, broken wires, or shorts, repair or replace the affected sections of the harness. Ensure all connections are clean, dry, and secure.
Replace sensor or module
If the wiring is in good condition and the sensor fails resistance checks, replace the sensor. Note that if the sensor is integrated into the DEF supply module or tank header assembly, the entire module or assembly must be replaced.
Clear fault codes
Use a diagnostic tool to clear the fault code from the EMR4 control module.
Perform system test
Start the engine and allow it to reach operating temperature. Monitor the DEF system parameters with a diagnostic tool to ensure the new sensor is reading correctly. A cold start cycle may be necessary to fully verify the fix.
Parts you might need
(7)DEF Supply Module Temperature Sensor / Tank Header Assembly
Often integrated into the DEF supply module. Must be sourced from a dealer using the machine's serial number.
DEF Sensor (10-gallon tank)
5100041353Wacker Neuson Deutz part; direct applicability to all Deutz-Fahr models is unconfirmed.
AdBlue Supply Module (Bosch Denoxtronic 2.2)
0444043073Verify fitment by serial number before ordering
- AdBlue Supply Module04600620
Verify fitment by serial number before ordering
- AdBlue Supply Module04609000
Verify fitment by serial number before ordering
AdBlue Supply Module
04609002Verify fitment by serial number before ordering
AdBlue Supply Module
04603859Verify fitment by serial number before ordering