944

Deutz-Fahr 944 – ECU: Sensor error burner temperature; signal range check low

Issue description

The Engine Control Unit (EMR4) has detected that the voltage signal from the burner firing chamber temperature sensor is below the normal operating range (SPN 523921, FMI 4). This indicates a potential short circuit to ground or a faulty sensor within the exhaust aftertreatment system.

Applies to these machines

  • TCD 3.6
  • EMR4 Equipped Machines
  • Genie
  • Bomag

Check the cause

  1. Ensure the engine is shut down, the exhaust system has cooled completely (can reach 650°C), and power is isolated (LOTO) to prevent severe burns.

  2. Visually inspect the wiring harness and connector for the burner temperature sensor for chafing, melting, corrosion, or loose pins.

  3. Use a multimeter to check for continuity between the sensor's signal wire and chassis ground to identify any short circuits.

  4. Disconnect the sensor and measure its internal resistance with a multimeter. An open circuit (infinite resistance) or short circuit (zero resistance) indicates a faulty sensor. General flame sensors can also be tested for a microamp (µA) signal when the flame is present.

Repair steps

  1. Isolate and secure machine

    Ensure the machine is powered off and all safety and lockout/tagout procedures are followed before working near the exhaust.

  2. Access the sensor

    Locate the burner assembly within the exhaust aftertreatment system. The temperature sensor is a small probe threaded into the burner housing.

  3. Perform Diagnostic Tests

    Conduct the visual inspection and electrical tests as described in the diagnostic checks.

  4. Repair wiring harness

    If a short circuit to ground or physical damage was found during inspection, repair or replace the affected section of the wiring harness. Ensure all connections are clean and secure.

  5. Replace temperature sensor

    If the sensor failed the resistance test, carefully unscrew it from the burner housing and install the correct replacement part.

  6. Clear fault codes

    Reconnect the battery, start the engine, and use a diagnostic tool such as Deutz SerDia to clear the fault code from the ECU memory.

  7. Verify repair

    Operate the machine to ensure the code does not return. A forced DPF regeneration may be necessary to verify the burner and sensors function correctly under load.