I25

Deutz-Fahr I25 – Instrument Panel (DIGITEK) / Dashboard ECU: Power output 0 short circuit to battery

Issue description

The control unit has detected that the preheating control relay (designated as RL42) is short-circuiting to the battery positive (Vcc).

Applies to these machines

  • Agroplus 310, 320, 410, and 420 Profiline series tractors
  • Deutz-Fahr Agrofarm series (85, 100, 410, 420, 430)
  • Deutz-Fahr 5000 Series (L11)
  • Deutz-Fahr Agrotron series
  • SAME Explorer 90 / Virtus models

Check the cause

  1. Visually inspect contacts on connector '5K' (at the instrument panel) and connector 'RL42' (at the preheating control relay) to ensure they are firmly secured and not oxidized.

  2. Perform a continuity test with the starter key OFF: disconnect connector '5K' and measure resistance between pin 2 of connector 'RL42' and pin 19 of connector '5K' (should be 0 Ohms).

  3. Test the preheating control relay independently to ensure it is not internally shorted to battery voltage.

  4. Inspect the wiring harness between the instrument panel and the relay for any chafing or melted insulation that could cause a short to a 12V+ source.

Repair steps

  1. Disconnect Battery

    Always disconnect the negative battery terminal before performing electrical repairs to prevent further shorting.

  2. Clean Contacts

    If oxidation was found during the diagnostic checks on connector 5K or RL42, clean the pins with electrical contact cleaner and apply dielectric grease.

  3. Repair Wiring

    If the continuity test fails or a short to battery positive is found in the harness between pin 19 (5K) and pin 2 (RL42), repair or splice the damaged section of the wiring harness.

  4. Replace Relay

    If the wiring is intact but the relay is internally shorted, replace the preheating control relay (RL42).

  5. Clear Codes

    Reconnect the battery. Clear all alarms using the SERDIA diagnostic software/tool, or cycle the starter key first to 'O' (OFF) and then to 'I' (ON) to verify if the alarm returns.

Parts you might need

(4)
  • Preheating Control Relay / Glow Plug Control Unit

    01179712

    Also crosses to Bosch # 0281003007. Fitment: Agrofarm, Agrotron, and Agroplus series.

  • Alternative Preheat Relay

    01179713

    Depending on exact engine configuration, e.g., BF4M/TCD series.

  • Alternative Preheat Relay

    04213435

    Depending on exact engine configuration, e.g., BF4M/TCD series.

  • Ignition Switch

    044115124

    Alternative # 00150485. Use if the short originates from a faulty key switch.

Get help to fix this fault by requesting a quote

Browse other Deutz-Fahr codes