Deutz-Fahr I37 – Instrument Panel (Dash): Relay fault within the engine preheating (glow plug) circuit
Issue description
The instrument panel detects that the preheating device is off when it is commanded to be on, or that the preheating control relay is disconnected or short-circuiting to ground.
Applies to these machines
11 machines- Agroplus 310, 320, 410, and 420 Profiline series tractors
- Agrofarm 85
- Agrofarm 100
- Agrofarm 410
- Agrofarm 420
- Agrofarm 430
- Agrotron
- Agroplus
- 5C series
- 5G series
- 6C series
Check the cause
Visually inspect the contacts on connector '5K' at the instrument panel and connector 'RL42' at the preheating control relay for oxidation or corrosion.
Perform a continuity test between pin 2 of connector 'RL42' and pin 19 of connector '5K' (should read 0 Ohms).
Test the circuit for continuity to the chassis ground to rule out a shorted wire harness.
Bench test the preheating control relay (RL42) by applying 12V to the coil pins and verifying that the load contacts close with minimal resistance.
Repair steps
Disconnect Power
Disconnect the battery terminals (negative terminal first) before working on the tractor's electrical system to prevent short circuits.
Access the Components
Remove the necessary dash trim to access the rear of the instrument panel (Connector 5K) and the relay panel to access the preheating control relay (RL42).
Clean Contacts
If oxidation was found during the diagnostic checks, use a dedicated electrical contact cleaner to clean the pins on both the relay socket and the instrument panel connector.
Repair Wiring
If the continuity test failed, trace the wire between pin 19 of the dash and pin 2 of the relay. Repair any chafed, broken, or melted sections of the harness.
Replace the Relay
If the wiring is intact but the relay failed the bench test (or if the internal coil is shorted to ground), replace relay RL42 with a new OEM unit.
Reassembly and Clearing Codes
Reconnect all plugs, then reconnect the battery (positive first, then negative). Clear all alarms from the dash.
Verify Repair
Turn the starter key to 'I' (ON) while the engine is cold (below 30°C) and verify that the preheating light illuminates and the relay clicks on without triggering the I37 code.
Parts you might need
(1)Preheating Control Relay / Relay Control Unit
01179712Fits Deutz-Fahr Agrofarm (85-100, 420-430), Agrotron, Agroplus, and 5C/5G/6C series tractors.
Get help to fix this fault by requesting a quote