P1151-00
Deutz-Fahr P1151-00: Machine-specific digital output 2 - Short circuit to ground (high side)
Issue description
A short circuit to ground on the high side of machine-specific digital output 2 has been detected. This indicates an electrical fault in the circuit associated with this output.
Check the cause
The wiring and connections of machine-specific digital output 2
The component identified by this code
The affected circuit
Repair steps
Inspect
Inspect the wiring and connections of machine-specific digital output 2 for damage, wear, or improper connections.
Test
Test the component identified by this code for proper functionality and continuity.
Check
Check the affected circuit for signs of a short to ground, including insulation damage or foreign material.
Parts you might need
(0)Get help to fix this fault by requesting a quote