P1161-00
Deutz-Fahr P1161-00: NH3 Sensor - Resistance Error
Issue description
The system has detected a resistance error related to the NH3 sensor. This indicates a potential issue with the sensor's electrical resistance, which may affect its proper operation.
Check the cause
The NH3 sensor wiring and connections
The NH3 sensor itself for damage or malfunction
Repair steps
Inspect
Check the wiring and connections of the NH3 sensor for any signs of damage, corrosion, or loose contact.
Test
Use a multimeter to measure the resistance of the NH3 sensor and compare it to the manufacturer's specifications.
Replace
If the sensor is found to be faulty, replace it with a compatible NH3 sensor.
Parts you might need
(0)Get help to fix this fault by requesting a quote