P1167-00
Deutz-Fahr P1167-00: Emergency Stop - Ignition on while Emergency Stop is Active
Issue description
The system has detected that the ignition is on while the emergency stop is active. This condition may prevent the machine from operating safely and requires immediate attention.
Check the cause
The status of the emergency stop mechanism
The ignition switch position
The connection between the emergency stop and the ignition system
Repair steps
Verify the emergency stop status
Ensure the emergency stop is fully released and not engaged.
Check the ignition switch
Confirm that the ignition switch is in the correct position and not faulty.
Inspect the connection between the emergency stop and the ignition system
Check for any loose or damaged wiring or components in the circuit.
Parts you might need
(0)Get help to fix this fault by requesting a quote