P1167-00

Deutz-Fahr P1167-00: Emergency Stop - Ignition on while Emergency Stop is Active

Issue description

The system has detected that the ignition is on while the emergency stop is active. This condition may prevent the machine from operating safely and requires immediate attention.

Check the cause

  1. The status of the emergency stop mechanism

  2. The ignition switch position

  3. The connection between the emergency stop and the ignition system

Repair steps

  1. Verify the emergency stop status

    Ensure the emergency stop is fully released and not engaged.

  2. Check the ignition switch

    Confirm that the ignition switch is in the correct position and not faulty.

  3. Inspect the connection between the emergency stop and the ignition system

    Check for any loose or damaged wiring or components in the circuit.