Deutz-Fahr P1375-00: Machine-specific digital output 2 - Electrical error
Issue description
The system has detected an electrical error related to machine-specific digital output 2. This fault indicates a problem with the electrical signal or connection associated with this output.
Check the cause
The wiring and connections associated with machine-specific digital output 2
The power supply to the circuit containing machine-specific digital output 2
The component or system that receives the signal from machine-specific digital output 2
Repair steps
Inspect
Inspect the wiring and connections for machine-specific digital output 2 for damage, corrosion, or loose connections.
Test
Test the power supply to the circuit containing machine-specific digital output 2 using a multimeter or appropriate testing device.
Verify
Verify the functionality of the component or system that receives the signal from machine-specific digital output 2.
Parts you might need
(0)Get help to fix this fault by requesting a quote