P13CF-00
Deutz-Fahr P13CF-00: Machine-specific lamp output 3 - Short circuit to battery (high side)
Issue description
A short circuit to battery (high side) has been detected in the machine-specific lamp output 3. This condition may cause improper operation or damage to the electrical system.
Check the cause
The wiring and connections associated with machine-specific lamp output 3
The lamp or component connected to machine-specific lamp output 3
The affected circuit
Repair steps
Inspect
Inspect the wiring and connections associated with machine-specific lamp output 3 for damage, wear, or improper connections.
Test
Test the lamp or component connected to machine-specific lamp output 3 for faults or short circuits.
Isolate
Isolate the affected circuit to determine if the short circuit is localized or part of a larger issue.
Parts you might need
(0)Get help to fix this fault by requesting a quote