P13CF-00

Deutz-Fahr P13CF-00: Machine-specific lamp output 3 - Short circuit to battery (high side)

Issue description

A short circuit to battery (high side) has been detected in the machine-specific lamp output 3. This condition may cause improper operation or damage to the electrical system.

Check the cause

  1. The wiring and connections associated with machine-specific lamp output 3

  2. The lamp or component connected to machine-specific lamp output 3

  3. The affected circuit

Repair steps

  1. Inspect

    Inspect the wiring and connections associated with machine-specific lamp output 3 for damage, wear, or improper connections.

  2. Test

    Test the lamp or component connected to machine-specific lamp output 3 for faults or short circuits.

  3. Isolate

    Isolate the affected circuit to determine if the short circuit is localized or part of a larger issue.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other Deutz-Fahr codes