Deutz-Fahr P2034-13: Exhaust gas temperature sensor (upstream SCR) 2 - Open circuit
Issue description
The system has detected an open circuit in the exhaust gas temperature sensor located upstream of the SCR. This fault indicates a loss of electrical continuity in the sensor's circuit, which may prevent accurate temperature monitoring and affect emissions control.
Check the cause
The wiring and connections to the exhaust gas temperature sensor (upstream SCR) 2
The integrity of the sensor's circuit
The sensor's mounting and physical condition
Repair steps
Inspect
Check the wiring and connections to the exhaust gas temperature sensor (upstream SCR) 2 for damage, corrosion, or disconnection.
Test
Use a multimeter to test the continuity of the circuit connected to the exhaust gas temperature sensor (upstream SCR) 2.
Replace
If the circuit is open or damaged, replace the exhaust gas temperature sensor (upstream SCR) 2 as needed.