P2060-00

Deutz-Fahr P2060-00: SCR System Air Pump/Air Supply Valve Short Circuit to Ground (High Side)

Issue description

A short circuit to ground on the high side of the SCR system air pump or air supply valve has been detected. This fault may affect the proper operation of the SCR system, potentially leading to reduced performance or failure to meet emissions standards.

Check the cause

  1. The wiring and connections related to the air pump and air supply valve

  2. The integrity of the circuit for the air pump and air supply valve

  3. The component identified by this code for signs of damage or wear

Repair steps

  1. Inspect

    Inspect the wiring and connections for the air pump and air supply valve for damage, corrosion, or loose connections.

  2. Test

    Test the circuit for the air pump and air supply valve using a multimeter to confirm the presence of a short to ground.

  3. Replace

    If a short is confirmed, replace the affected component identified by this code.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other Deutz-Fahr codes