P2A00-64

Deutz-Fahr P2A00-64: NOx Sensor (Upstream SCR) - Sensor Removed from Exhaust Line

Issue description

The NOx sensor located upstream of the SCR has been removed from the exhaust line. This condition may affect the proper monitoring of exhaust emissions and the operation of the emission control system.

Check the cause

  1. Verify the physical presence of the NOx sensor in the exhaust line

  2. Check for any signs of tampering or disconnection

  3. Confirm the sensor is properly installed and secured

Repair steps

  1. Inspect the exhaust line

    Check the location of the NOx sensor to ensure it is installed in the correct position within the exhaust line.

  2. Reinstall the NOx sensor

    If the sensor is missing, reinstall it according to the manufacturer's specifications.

  3. Verify sensor connection

    Ensure the sensor is properly connected and secured to prevent future dislodgement.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other Deutz-Fahr codes