P3033-92

Deutz-Fahr P3033-92: NOx Sensor (Downstream SCR) 5 - Offset Error

Issue description

The system has detected an offset error in the NOx sensor located downstream of the SCR. This indicates a deviation from the expected performance of the sensor, which may affect emissions control and engine performance.

Check the cause

  1. The NOx sensor (downstream SCR) for physical damage or contamination

  2. The wiring and connections to the NOx sensor (downstream SCR) for integrity

  3. The calibration of the NOx sensor (downstream SCR) according to the service manual

Repair steps

  1. Inspect

    Visually inspect the NOx sensor (downstream SCR) for signs of damage, corrosion, or contamination.

  2. Check

    Verify the integrity of the wiring and connectors associated with the NOx sensor (downstream SCR).

  3. Calibrate

    Follow the service manual procedures to recalibrate the NOx sensor (downstream SCR) if necessary.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other Deutz-Fahr codes