P3085-64

Deutz-Fahr P3085-64: NOx Sensor (Upstream SCR) 2 - Sensor Removed from Exhaust Line

Issue description

The NOx sensor (upstream SCR) 2 has been detected as removed from the exhaust line. This condition may affect the proper monitoring of exhaust emissions and the operation of the selective catalytic reduction system.

Check the cause

  1. Verify the physical presence of the NOx sensor (upstream SCR) 2 in the exhaust line.

  2. Check for any signs of disconnection or damage to the sensor or its mounting location.

Repair steps

  1. Reinstall the NOx sensor (upstream SCR) 2 into the exhaust line.

    Ensure the sensor is properly seated and secured according to the manufacturer's specifications.

  2. Inspect the sensor wiring and connections.

    Check for any damage, corrosion, or loose connections that may have contributed to the sensor being removed.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other Deutz-Fahr codes