00.1.4F

Fendt 00.1.4F – A007 - Instrument cluster: Checksum GD table

Issue description

Internal memory (EEPROM) in the instrument cluster is faulty or corrupted, resulting in a display error on the instrument panel.

Applies to these machines

  • 309 Vario COM III
  • 310 Vario COM III
  • 311 Vario COM III
  • 312 Vario COM III
  • 922 Vario COM III
  • 924 Vario COM III
  • 927 Vario COM III
  • 930 Vario COM III
  • 933 Vario COM III
  • 936 Vario COM III
  • Fendt 300 Vario COM III
  • 309
  • 310
  • 311
  • 312
  • Fendt 400 Vario COM III
  • Fendt 700 Vario COM III
  • Fendt 800 Vario COM III
  • Fendt 900 Vario COM III
  • 916
  • 920
  • 922
  • 924
  • 926
  • 930
  • 936

Check the cause

  1. Verify power and ground to the A007 module to ensure stable voltage, specifically inspecting fuses F040 and F041 on the A013 printed circuit board.

  2. Read and clear faults using the multiple display or FENDIAS software to determine if the code was a transient voltage glitch or a hard memory failure.

  3. Check for related A007 codes, such as 00.1.50 (EEPROM not programmed) or 00.0.20 (CAN bus fault), to isolate internal memory issues from communication failures.

Repair steps

  1. Perform EOL Programming

    The official OEM remedy for fault code 00.1.4F is to perform EOL (End-Of-Line) programming.

  2. Connect diagnostic tool

    Connect the FENDIAS diagnostic tool to the tractor.

  3. Initiate EOL programming sequence

    Initiate the EOL programming sequence for the A007 Instrument Cluster to re-flash the EEPROM and correct the checksum mismatch.

  4. Assess hardware failure

    If the EOL programming fails to write, or if the fault returns immediately upon rebooting the tractor, the physical EEPROM chip inside the cluster has failed.

  5. Remove instrument cluster

    Remove the A007 instrument cluster from the dashboard.

  6. Repair or replace cluster

    The cluster must either be sent to a specialized agricultural electronics repair facility (such as Ilgenfritz Mechatronics) or replaced entirely with a new unit.

  7. Program new unit

    If a new unit is installed, EOL programming will still be required to marry the new cluster to the tractor's basic control unit (A050).

Parts you might need

(5)
  • A007 Instrument Cluster / Instrument Panel

    VDO (Continental). Exact OEM part number varies depending on the specific Vario series and cab configuration.

  • LCD screen and ribbon cable

    X833020002

    Aftermarket replacement LCD screen and ribbon cable.

  • LCD screen and ribbon cable

    X833020003

    Aftermarket replacement LCD screen and ribbon cable.

  • LCD screen and ribbon cable

    X833020004

    Aftermarket replacement LCD screen and ribbon cable.

  • LCD screen and ribbon cable

    X833020005

    Aftermarket replacement LCD screen and ribbon cable.

Get help to fix this fault by requesting a quote