00.1.50

Fendt 00.1.50 – A007 - Instrument Cluster: VDO instrument cluster - EEPROM not programmed

Issue description

The internal memory (EEPROM) of the instrument cluster has lost its configuration data, suffered a checksum error, or failed to retain its End of Line (EOL) programming. As a result, the instrument cluster will experience display malfunctions or fail to operate correctly.

Applies to these machines

  • 309 Vario COM III
  • 310 Vario COM III
  • 311 Vario COM III
  • 312 Vario COM III
  • 922 Vario COM III
  • 924 Vario COM III
  • 927 Vario COM III
  • 930 Vario COM III
  • 933 Vario COM III
  • 936 Vario COM III
  • Fendt 300 Vario series (309, 310, 311, 312)
  • Fendt 400 Vario / Farmer 400 series (409, 410, 411, 412)
  • Fendt 700 Vario / Favorit 700 series (711, 712, 714, 716, 718, 720, 722, 724)
  • Fendt 800 Vario series (815, 817, 818, 820)
  • Fendt 900 Vario / Favorit 900 series (916, 920, 924, 926, 930)

Check the cause

  1. Verify the power supply to the CAN bus and the instrument cluster. Check circuit board A013, specifically inspecting fuses F040 and F041, as voltage drops can cause memory faults.

  2. Look for accompanying A007 checksum fault codes (e.g., 00.1.4D, 00.1.4E, 00.1.4F), which indicate specific memory failures for menu icons or warning images.

  3. Attempt to clear the codes using FENDIAS diagnostic software to determine if the EEPROM error is a hard fault or a temporary glitch.

Repair steps

  1. Connect Diagnostic Tool

    Connect the tractor to the official FENDIAS diagnostic software.

  2. Perform EOL Programming

    Navigate to the instrument cluster (A007) module and initiate an EOL (End of Line) reprogramming sequence. This will attempt to re-flash the EEPROM with the correct tractor configuration data.

  3. Verify Repair

    Cycle the key and check if the instrument cluster retains the programming and clears the 00.1.50 fault code.

  4. Hardware Replacement (If Programming Fails)

    If the EOL programming fails to write to the EEPROM, the internal memory chip or microcontroller has physically failed. Disconnect the battery (negative terminal first).

  5. Remove the Cluster

    Remove the dashboard trim and extract the A007 instrument cluster.

  6. Repair or Replace

    You must either send the VDO instrument cluster to a specialized agricultural electronics repair center for a microcontroller/EEPROM board repair, or replace the entire instrument cluster assembly.

  7. Program New Unit

    If a new or remanufactured cluster is installed, you must perform EOL programming on the new unit via FENDIAS to pair it with the tractor's basic control unit.

Parts you might need

(4)
  • Instrument Cluster Assembly

    G339970010018

    AGCO Part Number: 72617625

  • Instrument Cluster Assembly

    72617625

    AGCO Part Number

  • Remanufactured VDO instrument cluster

    G339.970.010.014
  • Display / Instrument cluster

    G312970010052

    Varies by exact chassis/COM generation

Get help to fix this fault by requesting a quote