00.1.78

Fendt 00.1.78 – Instrument Cluster / Overall System ECU: A037 (or A036) - Control panel, dashboard left: Down button pressed > 30s

Issue description

The system has detected that the "Down" key on the left dashboard control panel has been continuously actuated (closed circuit) for more than 30 seconds. The system logic assumes the button is physically stuck, mechanically broken, or electrically shorted. As a safety precaution, the tractor's computer renders the button non-operable until the fault is resolved.

Applies to these machines

  • 922 Vario COM III
  • 924 Vario COM III
  • 927 Vario COM III
  • 930 Vario COM III
  • 933 Vario COM III
  • 936 Vario COM III
  • 207 Vario
  • 208 Vario
  • 209 Vario
  • 210 Vario
  • 211 Vario
  • 309 Vario
  • 310 Vario
  • 311 Vario
  • 312 Vario
  • 409 Vario
  • 410 Vario
  • 411 Vario
  • 412 Vario
  • 711 Vario
  • 712 Vario
  • 714 Vario
  • 716 Vario
  • 718 Vario
  • 815 Vario
  • 817 Vario
  • 818 Vario
  • 820 Vario
  • 916 Vario
  • 920 Vario
  • 922 Vario
  • 924 Vario
  • 926 Vario
  • 927 Vario
  • 930 Vario
  • 933 Vario
  • 936 Vario

Check the cause

  1. Inspect the 'Down' button on the left dashboard control panel for dirt, sticky residue, or debris that might be holding it down

  2. Press the button manually to check if it feels collapsed, lacks a normal 'click,' or fails to spring back into its neutral position

  3. Disconnect the A037 control panel and perform an electrical continuity test on the pins corresponding to the 'Down' button to check for an internal short

  4. Inspect the wiring harness and connector behind the A037 panel for chafing, pinched wires, or moisture ingress causing a short to ground

Repair steps

  1. Power Down

    Turn off the tractor ignition and disconnect the battery to prevent electrical spikes.

  2. Remove the Panel

    Carefully pry or unscrew the A037 left dashboard control panel from the side console/dashboard housing.

  3. Disconnect

    Unplug the electrical harness connector from the rear of the panel.

  4. Clean (If Applicable)

    If the button is physically stuck due to debris, use electrical contact cleaner and compressed air to clean the switch housing. Re-test the button's mechanical action.

  5. Replace

    If the button is internally shorted or physically broken, the control panel assembly must be replaced.

  6. Reinstall

    Connect the wiring harness to the new/cleaned control panel and snap or screw it back into the dashboard.

  7. Clear Codes

    Reconnect the battery and turn on the ignition. Test the "Down" button. Use the FENDIAS diagnostic tool to clear the inactive 00.1.78 fault code from the instrument cluster memory.

Parts you might need

(1)
  • Left Dashboard Control Panel / Switch Console (Component A037 / A036)

    Look up the specific A037 panel in the AGCO/Fendt parts catalog using the tractor's exact chassis serial number (VIN). Ensure the replacement panel matches the exact button layout of the original unit.

Get help to fix this fault by requesting a quote