01.1.7F

Fendt 01.1.7F – EDC (Electronic Diesel Control) Engine Control Unit: A036 - Control console: Hand throttle memory keys faulty (electric fault)

Issue description

The system has lost communication with the A036 control console, specifically isolating an electrical fault within the hand throttle memory buttons. The tractor will retain its last speed setting. The engine speed can no longer be adjusted using the memory keys, but it can still be changed manually using the hand throttle or foot throttle pedal.

Applies to these machines

  • 309 Vario COM III
  • 310 Vario COM III
  • 311 Vario COM III
  • 312 Vario COM III
  • Fendt 300 Vario
  • Fendt 400 Vario
  • Fendt 700 Vario
  • Fendt 800 Vario
  • Fendt 900 Vario

Check the cause

  1. Read fault memory using the Fendt SERDIA program to check for accompanying CAN bus or voltage errors

  2. Verify the voltage supply to the A036 control console and check the 500 mA microfuses on the A013 PCB (fuse board)

  3. Inspect the wiring harness between the A036 control console and the EDC control unit, specifically checking separation points X1357 and X1358 for corrosion, loose pins, or discontinuities

  4. Measure the terminating resistance and voltage on the Enhanced Controls Bus (K-bus) and Transmission Bus (G-bus) to ensure the network is intact

Repair steps

  1. Disconnect Power

    Turn off the ignition and disconnect the battery to prevent electrical spikes.

  2. Access the Console

    Remove the necessary trim panels on the right-hand mudguard or B-pillar to access the underside of the A036 control console.

  3. Clean and Reseat Connectors

    Disconnect the X1357/X1358 separation points. Clean the contacts with electrical contact cleaner, apply dielectric grease, and reseat them. Reconnect the battery and test.

  4. Replace or Repair the Console

    If the wiring is intact and the fault persists, the internal circuitry of the A036 hand throttle memory keypad has failed. Remove the defective A036 control console assembly.

  5. Install the Part

    Install the replacement console and reconnect the wiring harnesses.

  6. Clear Faults

    Turn on the ignition. Use the dashboard terminal or the SERDIA diagnostic tool to clear the stored fault codes. (Note: Canceling a fault message on the dash only hides it; it must be actively cleared from the EDC memory).

  7. Test

    Perform a functional test of the hand throttle memory keys to verify the repair.