Fendt 03.1.40 – A039 / A100 (MFA, multifunction armrest): Invalid parameters for hand throttle and throttle pedal speed range.
Issue description
The system has detected that the calibration values for the accelerator pedal resolution or hand throttle are out of range, missing, or corrupted (such as an EEPROM checksum error). As a safety consequence, the tractor's computer ignores the erratic sensor inputs and uses predefined default values. This typically results in the throttle pedal mode becoming inoperable or restricted, and the TMS (Tractor Management System) may be switched off.
Applies to these machines
28 machines- 922 Vario COM III
- 924 Vario COM III
- 927 Vario COM III
- 930 Vario COM III
- 933 Vario COM III
- 936 Vario COM III
- 300 Vario (COM III, S4)
- 400 Vario (COM III)
- 500 Vario (S4)
- 700 Vario (COM III, SCR)
- 800 Vario (COM III, S4)
- 900 Vario (COM III, S4)
- 922
- 924
- 927
- 930
- 933
- 936
- 409
- 410
- 411
- 412
- 1000 Vario S4
- 1038
- 1042
- 1046
- 1050
- 200 Vario
Check the cause
Verify the A034 driving switch/joystick accelerator pedal release potentiometer (slide switch) for physical damage, debris, or sticking.
Check for active vs. stored codes to determine if the module simply lost its calibration memory (e.g., due to a recent battery replacement or armrest disconnection).
Attempt a software calibration before replacing any hardware, as the code specifically points to invalid parameters.
Repair steps
Access diagnostic menu
Turn the ignition on and access the tractor's diagnostic/calibration menu via the terminal.
Check preliminary conditions
Ensure preliminary conditions are met (e.g., engine speed, transmission in neutral, emergency control not engaged).
Enter calibration code
Enter Calibration Code 4010 (Accelerator pedal resolution / driving pedal resolution).
Cycle controls
Follow the on-screen prompts to cycle the hand throttle and foot pedal through their full ranges of motion.
Save calibration data
If the calibration proceeds without errors, the message 'OK' is displayed, and the new sensor settings are stored in the EEPROM. Turn the ignition key to position 0 to save the data.
Troubleshoot calibration failures
If the terminal displays 'ERROR' or throws a secondary calibration fault code (e.g., F01: Conditions not met, F02: Calibrated value invalid, F03: MFA not responding, F08: Calibration taking too long), the physical potentiometer, wiring harness, or the MFA module itself is defective.
Replace hardware
If calibration fails repeatedly, replace the faulty MFA multifunction armrest or the specific slide switch component.
Perform post-repair programming
If the MFA armrest (A039/A100) is replaced, you must perform EOL (End of Line) programming using FENDIAS dealer software, followed by a complete block of calibrations (including 4010).
Parts you might need
(5)MFA Multifunction Armrest
931970160118Arm Rest for 900 Vario series: 922, 924, 927, 930, 933, 936
MFA Multifunction Armrest
F716501030220Arm Rest for Farmer 400 Vario series: 409, 410, 411, 412
MFA Multifunction Armrest
F931970160042Arm Rest Comfort Module for 1000 Vario S4 series: 1038, 1042, 1046, 1050
MFA Multifunction Armrest
G718970160110TMS Armrest - General Vario
MFA Multifunction Armrest
F260970160200Armrest Control Unit for 200 Vario
Get help to fix this fault by requesting a quote