Fendt 03.1.60 – MFA (Multifunction Armrest) control module: A039 - MFA, multifunction armrest
Issue description
Invalid parameters for the REAR power lift module. Because the system cannot read the correct parameters, it defaults to using predefined/default values to maintain basic functionality.
Applies to these machines
10 machines- 922 Vario COM III
- 924 Vario COM III
- 927 Vario COM III
- 930 Vario COM III
- 933 Vario COM III
- 936 Vario COM III
- Fendt 300 Vario series
- Fendt 700 Vario SCR series
- Fendt 800 Vario SCR series
- Fendt 900 Vario COM III / SCR series
Check the cause
Verify the active code 03.1.60 on the terminal display and check if the rear power lift is operating strictly on default values rather than responding to user-defined parameter adjustments.
Ensure there are no broader CAN bus communication errors between the MFA and the rear power lift module (which would typically trigger a '00.0.03' or similar bus fault).
Repair steps
Connect diagnostic tool
Connect the FENDIAS diagnostic laptop/tool to the tractor's diagnostic port.
Navigate to MFA programming
Navigate to the MFA (Multifunction Armrest) module programming section.
Perform EOL programming
Perform an EOL (End-Of-Line) programming procedure.
Enter calibration code
Specifically, enter Calibration code '8001' to rewrite the correct parameters for the rear power lift module into the MFA.
Clear fault code
Clear the stored fault code from the system memory (note: each stored fault code must be cleared individually).
Test rear power lift
Test the rear power lift to ensure it responds to user parameters and no longer relies on predefined values.
Parts you might need
(3)Multifunction Armrest (MFA) Comfort Module / Armrest Unit
F931970160042Fendt Arm Rest Comfort Module / EHR Knob Module
Multifunction Arm Rest
931970160118 / G931970160118fits 900 Vario series
Full Armrest Unit with Front Hitch Comfort
G716970070020fits 700 Vario series
Get help to fix this fault by requesting a quote