04.1.50

Fendt 04.1.50 – Transmission Control Unit (Transmission TCU / EST Module): S017 - 'Transmission oil filter clogged' switch

Issue description

The transmission oil filter is clogged or heavily contaminated. The system logs this when the S017 switch detects restricted flow/pressure changes indicative of a blocked filter.

Applies to these machines

  • 309 Vario COM III
  • 310 Vario COM III
  • 311 Vario COM III
  • 312 Vario COM III
  • 922 Vario COM III
  • 924 Vario COM III
  • 927 Vario COM III
  • 930 Vario COM III
  • 933 Vario COM III
  • 936 Vario COM III
  • 309 Vario
  • 310 Vario
  • 311 Vario
  • 312 Vario
  • 409 Vario
  • 410 Vario
  • 411 Vario
  • 412 Vario
  • 711 Vario
  • 712 Vario
  • 714 Vario
  • 716 Vario
  • 815 Vario
  • 817 Vario
  • 818 Vario
  • 916 Vario
  • 920 Vario
  • 922 Vario
  • 924 Vario
  • 926 Vario
  • 927 Vario
  • 930 Vario
  • 933 Vario
  • 936 Vario

Check the cause

  1. Check transmission oil temperature (must be above 50°C/122°F for the S017 switch to be active)

  2. Physically inspect the transmission oil filter for actual contamination, sludge, or debris

  3. Perform a plausibility check on the S017 switch (e.g., if it shows contamination when the engine is off, the switch is likely stuck)

  4. Test the wiring harness linking the S017 switch to the TCU for short-circuits, open circuits, or signal line faults

Repair steps

  1. Warm Up the Machine

    Run the tractor until the transmission oil temperature exceeds 50°C to ensure the S017 switch circuit is active.

  2. Service the Filter

    Drain the necessary fluid and remove the transmission oil filter. Clean the housing and install a new transmission oil filter.

  3. Test the System

    Clear the fault codes and operate the tractor. If the fault code 04.1.50 does not return, the issue was simply a dirty filter.

  4. Test the Switch

    If the filter is brand new and the code immediately returns, use a multimeter to test the S017 filter contamination switch for proper resistance and verify the 8.5V supply/ground at the connector.

  5. Replace the Switch

    If the switch fails the continuity/plausibility test (e.g., reading closed when there is no pressure differential), replace the S017 switch.

Parts you might need

(4)
  • Transmission Oil Filter

    F916100600010

    Fitment depends on the specific Vario series/chassis number

  • Transmission Oil Filter

    F916100600011

    Fitment depends on the specific Vario series/chassis number

  • Transmission Oil Filter

    F916100490010

    Fitment depends on the specific Vario series/chassis number

  • S017 Filter Contamination Switch

    Must be ordered via the dealer using the chassis number and referencing component ID 'S017'

Get help to fix this fault by requesting a quote