Fendt 04.1.B2 – A002 / A050: Fault in EPROM programming (travel range selector I/II)
Issue description
EPROM programming is faulty, affecting the tractor's transmission ratio limiting. The primary consequence is that the travel range cannot be changed while driving.
Applies to these machines
9 machines- 309 Vario COM III
- 310 Vario COM III
- 311 Vario COM III
- 312 Vario COM III
- Fendt 300 Vario
- Fendt 400 Vario (including Farmer 400 and COM III)
- Fendt 700 Vario (including Favorit 700 and COM III)
- Fendt 800 Vario (including COM III)
- Fendt 900 Vario (including Favorit 900 and COM III)
Check the cause
Verify symptoms by confirming that the tractor is locked out of changing travel ranges (I/II) while in motion.
Check the A002/A050 ECU voltage supply and CAN bus communication, as voltage drops can sometimes trigger EPROM/memory faults.
Read active codes using the Fendt multiple display or FENDIAS diagnostic tool to verify if 04.1.B2 is the only code present.
Repair steps
Connect Diagnostic Tool
Connect the tractor to the FENDIAS diagnostic software.
Perform EOL Programming
Perform EOL (End-Of-Line) reprogramming on the A002 (or A050) ECU to restore the correct travel range selector parameters. This addresses the software/memory issue causing the fault.
Clear Fault Memory
Once the EOL programming is complete, clear the fault code using the FENDIAS diagnostic software. Note that fault codes stored in the A002/A050 ECU cannot be deleted via the dashboard terminal.
Test Drive
Drive the tractor and attempt to change the travel range (I/II) while in motion to verify the repair was successful.
ECU Replacement/Repair
If the ECU fails to accept the EOL programming, the EPROM or the entire control unit is defective and must be sent out for repair or replaced.
Parts you might need
(7)ECU, basic control unit (A050)
G737.970.070.035Must undergo EOL programming and parameter flashing specific to the exact chassis number of the tractor before it will function.
ECU, basic control unit (A050)
G737.970.070.037Must undergo EOL programming and parameter flashing specific to the exact chassis number of the tractor before it will function.
ECU, basic control unit (A050)
G835.970.070.014Must undergo EOL programming and parameter flashing specific to the exact chassis number of the tractor before it will function.
ECU, basic control unit (A050)
G931.970.070.032Must undergo EOL programming and parameter flashing specific to the exact chassis number of the tractor before it will function.
ECU, basic control unit (A050)
G931.970.070.033Must undergo EOL programming and parameter flashing specific to the exact chassis number of the tractor before it will function.
ECU, basic control unit (A050)
G931.970.070.046Must undergo EOL programming and parameter flashing specific to the exact chassis number of the tractor before it will function.
ECU, enhanced control (A002)
Must undergo EOL programming and parameter flashing specific to the exact chassis number of the tractor before it will function.
Get help to fix this fault by requesting a quote