04.1.E3

Fendt 04.1.E3 – A050 - ECU, basic control unit: Checksum error, parameter for throttle pedal mode.

Issue description

Stored parameters or calibration data for the foot throttle pedal within the control unit have become corrupted or are being read incorrectly. As a safety consequence, the tractor defaults to "Emergency mode" and the Tractor Management System (TMS) is automatically switched off.

Applies to these machines

  • 922 Vario COM III
  • 924 Vario COM III
  • 927 Vario COM III
  • 930 Vario COM III
  • 933 Vario COM III
  • 936 Vario COM III
  • Fendt 300 Vario (COM III)
  • Fendt 400 Vario (COM III) (Models 409, 410, 411, 412, 413, 414, 415)
  • Fendt 700 Vario (COM III) (Models 711, 712, 714, 716, 718)
  • Fendt 800 Vario (COM III) (Models 815, 817, 818, 820)
  • Fendt 900 Vario (COM III / S4) (Models 916, 919, 920, 922, 924, 925, 926, 927, 930, 933, 936, 939)

Check the cause

  1. Inspect the physical condition of the B055 Foot Throttle Sensor pedal assembly.

  2. Inspect the wiring harness and connectors between the B055 foot throttle sensor and the A050 ECU for breaks, corrosion, or short circuits.

  3. Connect the FENDIAS diagnostic tool to read the live voltage values from the B055 sensor to ensure the A050 is receiving the correct target values.

Repair steps

  1. Connect Diagnostic Tool

    Connect the Fendt FENDIAS diagnostic software to the tractor's diagnostic port.

  2. Perform EOL Programming

    Use FENDIAS to rewrite/re-flash the corrupted throttle pedal parameters in the A050 Basic Control Unit.

  3. Calibrate the Sensor

    After EOL programming, perform a calibration of the B055 foot throttle sensor through the tractor's operator terminal to ensure the ECU learns the correct idle and full-throttle voltage limits.

  4. Clear Fault Codes

    Delete the stored fault codes from the A050 (and A051 if applicable) using the diagnostic software.

  5. Test Drive

    Verify that the emergency mode is deactivated and the Tractor Management System (TMS) functions normally.

  6. ECU Repair/Replacement

    If the A050 ECU refuses to accept programming or has an internal hardware failure, the unit must be removed and sent to a specialized agricultural electronics repair service or replaced entirely.

Parts you might need

(8)
  • A050 Basic Control Unit

    G737.970.070.035

    Requires EOL programming and parameterization via FENDIAS upon installation.

  • A050 Basic Control Unit

    G737.970.070.037

    Requires EOL programming and parameterization via FENDIAS upon installation.

  • A050 Basic Control Unit

    G835.970.070.014

    Requires EOL programming and parameterization via FENDIAS upon installation.

  • A050 Basic Control Unit

    G931.970.070.032

    Requires EOL programming and parameterization via FENDIAS upon installation.

  • A050 Basic Control Unit

    G931.970.070.033

    Requires EOL programming and parameterization via FENDIAS upon installation.

  • A050 Basic Control Unit

    G931.970.070.046

    Requires EOL programming and parameterization via FENDIAS upon installation.

  • A050 Basic Control Unit

    R917006740

    Requires EOL programming and parameterization via FENDIAS upon installation.

  • B055 Foot Throttle Sensor / Pedal Assembly

    G350.810.420.013

    Secured by 4 bolts and a single electrical connector. Requires calibration via the operator terminal after installation.

Get help to fix this fault by requesting a quote