07.1.E2

Fendt 07.1.E2 – A050 - ECU, basic control unit: Error in checksum PW rise of front PTO

Issue description

The control unit has detected a checksum error in the stored parameters for the pulse width (PW) rise (the engagement curve/modulation) of the front Power Take-Off (PTO). When this fault is active, the system cannot rely on the stored engagement curve and will default to using standard, unoptimized default values for the front PTO.

Applies to these machines

  • 922 Vario COM III
  • 924 Vario COM III
  • 927 Vario COM III
  • 930 Vario COM III
  • 933 Vario COM III
  • 936 Vario COM III
  • Fendt 200 V/F/P Vario series (207, 208, 209, 210, 211)
  • Fendt 300 Vario series
  • Fendt 400 Vario series
  • Fendt 700 Vario series
  • Fendt 800 Vario series
  • Fendt 900 Vario series (922, 924, 927, 930, 933, 936, 939)

Check the cause

  1. Verify front PTO operation and check for harsher or uncalibrated clutch engagement

  2. Check for related A050 checksum errors (such as 07.1.E1, 07.1.E3, or 07.1.E4) which indicate broader memory corruption

  3. Connect the FENDIAS diagnostic system to read specific corrupted parameters and verify communication with the A050 module

Repair steps

  1. Connect FENDIAS

    Hook up the Fendt diagnostic laptop (FENDIAS) to the tractor's diagnostic port.

  2. Perform EOL Programming

    Re-flash or reprogram the A050 Basic Control Unit to rewrite the correct parameters and checksums for the front PTO.

  3. Clear Codes

    Once the EOL programming is complete, clear the stored fault codes from the tractor's memory.

  4. Test Operation

    Engage the front PTO to ensure the modulation is smooth and the fault code does not return.

  5. ECU Replacement/Repair

    If the EOL programming fails to resolve the checksum error, or if the ECU refuses to accept the programming, the A050 ECU has suffered an internal EEPROM/memory failure. Remove the unit and send it to a specialized agricultural electronics repair service or replace it entirely.

Parts you might need

(8)
  • Fendt Basic Control Unit (A050) / Component Box A050

    G737.970.070.035

    Fitment varies heavily depending on the exact tractor model and chassis serial number. Must undergo EOL programming via FENDIAS upon installation.

  • Fendt Basic Control Unit (A050) / Component Box A050

    G737.970.070.037

    Fitment varies heavily depending on the exact tractor model and chassis serial number. Must undergo EOL programming via FENDIAS upon installation.

  • Fendt Basic Control Unit (A050) / Component Box A050

    G835.970.070.014

    Fitment varies heavily depending on the exact tractor model and chassis serial number. Must undergo EOL programming via FENDIAS upon installation.

  • Fendt Basic Control Unit (A050) / Component Box A050

    G931.970.070.032

    Fitment varies heavily depending on the exact tractor model and chassis serial number. Must undergo EOL programming via FENDIAS upon installation.

  • Fendt Basic Control Unit (A050) / Component Box A050

    G931.970.070.033

    Fitment varies heavily depending on the exact tractor model and chassis serial number. Must undergo EOL programming via FENDIAS upon installation.

  • Fendt Basic Control Unit (A050) / Component Box A050

    G931.970.070.046

    Fitment varies heavily depending on the exact tractor model and chassis serial number. Must undergo EOL programming via FENDIAS upon installation.

  • Fendt Basic Control Unit (A050) / Component Box A050

    G260.970.070.082

    Fitment varies heavily depending on the exact tractor model and chassis serial number. Must undergo EOL programming via FENDIAS upon installation.

  • Fendt Basic Control Unit (A050) / Component Box A050

    R917006740

    Bosch reference number. Must undergo EOL programming via FENDIAS upon installation.

Get help to fix this fault by requesting a quote