Fendt 08.1.50 – Rear EPC: B031 - Right draft sensing pin, rear power lift
Issue description
The right draft sensing pin is overloaded. This is often the result of the lift twisting in the upper range (90-100% lift height) due to a mechanical setting that is too tight. The code can also be triggered by a signal line fault, a faulty sensor, or a failure in the reference supply voltage. Consequently, the tractor will reduce the load on the draft sensing pin, resulting in restricted control quality or limited performance during traction control, and may default to position control only.
Applies to these machines
11 machines- 309 Vario COM III
- 310 Vario COM III
- 311 Vario COM III
- 312 Vario COM III
- 300 Vario series
- 400 Vario series
- 700 Vario series
- 800 Vario series
- 900 Vario series
- 900 Vario series COM III
- 900 Vario series S4
Check the cause
Lower the rear power lift to relieve the physical draught/load on the right sensing pin to see if the fault clears
Check the rear power lift linkage for twisting or binding when it reaches the upper range (90-100% lift height) and ensure mechanical settings are not adjusted too tightly
Check the supply voltage to the B031 sensor using a multimeter (the Rear EPC ECU should supply 8.5 V, 9.5 V, or 10.0 V depending on the model)
Inspect the signal line and wiring harness between the B031 sensor and the Rear EPC ECU for open circuits or short circuits
Repair steps
Lower the Implement
Safely lower the rear power lift to the ground to remove all tension and load from the lower link bearing points.
Adjust Lift Settings
If the diagnostic checks revealed twisting in the upper lift range, adjust the mechanical linkage settings to prevent binding at 90-100% lift height.
Test the Circuit
Disconnect the B031 right draft sensing pin. Test the wiring harness for continuity and verify the correct reference voltage from the ECU. Repair any damaged wiring.
Replace the Sensor
If the wiring and voltage are intact but the fault persists (or if the sensor is physically damaged/shorted), the B031 draft sensing pin is internally faulty. Remove the faulty pin from the right lower link and install the replacement draft sensing pin.
Reassembly and Calibration
Reconnect the sensor harness. Clear the stored fault codes from the terminal and test the electrohydraulic power lift control to ensure full traction control performance has been restored.
Parts you might need
(5)Draft Sensing Pin / Draft Sensor / Kraftmessbolzen
G930860070012Verify exact part number against chassis number in Fendt Epsilon parts catalog
Draft Sensing Pin / Draft Sensor / Kraftmessbolzen
G716860070013Verify exact part number against chassis number in Fendt Epsilon parts catalog
Draft Sensing Pin / Draft Sensor / Kraftmessbolzen
G931860070011Verify exact part number against chassis number in Fendt Epsilon parts catalog
Draft Sensing Pin / Draft Sensor / Kraftmessbolzen
G210861100070Verify exact part number against chassis number in Fendt Epsilon parts catalog
Draft Sensing Pin / Draft Sensor / Kraftmessbolzen
R917000160Bosch OEM draft sensor for Fendt and Massey Ferguson applications
Get help to fix this fault by requesting a quote