Fendt 08.1.51 – Rear EPC (ECU, EPC B (A024)): Left draft sensing pin, rear power lift – Draft sensing pin left overload.
Issue description
The system has detected that the left draft sensing pin (load pin) is overloaded. This often occurs as a result of twisting or binding in the lifting gear in the upper range (90-100% lift height) due to the mechanical settings being too tight. It can also indicate a signal line fault, a faulty sensor, or a supply voltage issue. Consequence: The system will restrict control quality during traction control, and only position control may be possible.
Applies to these machines
9 machines- 309 Vario COM III
- 310 Vario COM III
- 311 Vario COM III
- 312 Vario COM III
- Fendt 300 Vario (COM III)
- Fendt 400 Vario (COM III) / Farmer 400
- Fendt 700 Vario (COM III) / Favorit 700
- Fendt 800 Vario (COM III) / Favorit 800
- Fendt 900 Vario (COM III) / Favorit 900
Check the cause
Check the rear power lift for physical binding. Ensure the lift is not twisting in the upper range (90-100% lift height) due to overly tight mechanical settings.
Manually relieve the load on the left draft sensing pin to see if the fault clears.
Measure the supply voltage to the B032 sensor. Depending on the exact tractor series, the sensor requires a steady supply of 8.5V, 9.5V, or 10.0V (supplied from A013, A014, or A005).
Verify that the tractor's overall battery voltage is above 11.0V, as low voltage can trigger false EPC faults.
Check the signal line between the B032 sensor and the Rear EPC module for continuity, shorts to ground, or chafing.
Repair steps
Adjust Lift Settings
If the mechanical inspection reveals binding, adjust the rear power lift settings to prevent twisting at the maximum lift height.
Repair Wiring
If the signal line or supply voltage fails the diagnostic checks, repair the damaged wiring harness leading to the B032 sensor.
Replace Sensor
If the mechanical settings are correct, the wiring is intact, and the supply voltage is within specification (8.5V - 10.0V), the B032 draft sensing pin itself has failed internally and must be replaced.
Clear Codes
After replacing the pin or repairing the wiring, use the tractor's terminal or the FENDIAS diagnostic tool to clear the stored 08.1.51 fault code and recalibrate the rear power lift if necessary.
Parts you might need
(3)Left draft sensing pin / Load sensing pin / Kraftmessbolzen (links)
G931860070011Common on 800/900 series
Left draft sensing pin / Load sensing pin / Kraftmessbolzen (links)
G930860070012Left draft sensing pin / Load sensing pin / Kraftmessbolzen (links)
G716860070013Common on 700 series
Get help to fix this fault by requesting a quote