Fendt 08.1.B2 – A039 - MFA (Multifunction Armrest): A039 - MFA, multifunction armrest Setpoint value potentiometer, rear power lift
Issue description
The setpoint value potentiometer (rotary switch) for the rear power lift (Rear EPC / Electrohydraulic lifting gear control) is not calibrated. Because the potentiometer is uncalibrated, setpoint values can no longer be set, and the system defaults to allowing only position control.
Applies to these machines
29 machines- 922 Vario COM III
- 924 Vario COM III
- 927 Vario COM III
- 930 Vario COM III
- 933 Vario COM III
- 936 Vario COM III
- 300 Vario COM III
- 309
- 310
- 311
- 312
- 400 Vario COM III
- 700 Vario COM III
- 711
- 712
- 714
- 716
- 800 Vario COM III
- 815
- 817
- 818
- 900 Vario COM III
- 916
- 922
- 924
- 927
- 930
- 933
- 936
Check the cause
Verify the terminal display is requesting calibration code '8001' for the rear power lift setpoint value potentiometer
Check for underlying bus communication faults (e.g., 00.0.03 or 00.0.04) that would prevent successful calibration
Physically inspect the rotary switch/potentiometer on the A039 multifunction armrest for mechanical damage, sticking, or liquid intrusion
Consult the 'Electrohydraulic lifting gear control' circuit diagram to test signal integrity and wiring between the MFA and the basic control unit
Repair steps
Prepare the Tractor
Ensure the tractor is stationary, the engine is running (or ignition is ON as specified by the terminal prompt), and the rear power lift area is clear of bystanders.
Access Calibration Menu
Navigate to the tractor's terminal/dashboard calibration menu.
Run Calibration Code 8001
Enter and execute calibration code '8001' (Rear EPC calibration).
Follow Terminal Prompts
Move the setpoint value potentiometer through its full range of motion as instructed by the terminal to teach the module its minimum and maximum values.
Save and Clear
Once calibration is successful, save the values. Use the FENDIAS diagnostic software or the tractor's terminal to clear the 08.1.B2 fault code from the memory.
Hardware Replacement (If Calibration Fails)
If the potentiometer cannot be calibrated (e.g., due to an internal short or open circuit), the faulty potentiometer or the entire A039 Multifunction Armrest assembly must be replaced, followed by a repeat of the 8001 calibration.
Parts you might need
(1)A039 - MFA, Multifunction Armrest Assembly / Setpoint Value Potentiometer
Must be looked up in the Epsilon spare parts catalog using the specific tractor's chassis number. If replacing the entire A039 MFA, End-of-Line (EOL) programming may be required to pair the new armrest with the A050 Basic Control Unit.
Get help to fix this fault by requesting a quote