Fendt 09.1.B2 – A039 - MFA (Multifunction Armrest): A039 - MFA, multifunction armrest: Setpoint potentiometer, front power lift - Setpoint value potentiometer not calibrated.
Issue description
The system has lost the calibration values for the depth control setpoint dial/potentiometer used to operate the front power lift. The setpoint values cannot be set by the operator, and the front power lift will default to allowing only basic position control.
Applies to these machines
20 machines- 922 Vario COM III
- 924 Vario COM III
- 927 Vario COM III
- 930 Vario COM III
- 933 Vario COM III
- 936 Vario COM III
- Fendt 300 Vario (COM III)
- Fendt 400 Vario (COM III)
- Fendt 700 Vario (COM III / S4)
- Fendt 800 Vario (COM III / S4)
- Fendt 900 Vario (COM III / S4)
- Fendt 916
- Fendt 920
- Fendt 922
- Fendt 924
- Fendt 926
- Fendt 927
- Fendt 930
- Fendt 933
- Fendt 936
Check the cause
Check for accompanying fault code 09.1.B3, which indicates a hardware signal fault (potentiometer sending no values or incorrect values) rather than just a calibration loss.
Inspect the front power lift depth control setpoint potentiometer on the multifunction armrest for physical damage, sticking, or liquid intrusion.
Ensure the A039 MFA is communicating properly with the tractor's basic control unit (ECU A050) and that no general MFA bus faults are active.
Repair steps
Prepare tractor for calibration
Ensure the tractor is stationary, the engine is running at the specified RPM (usually around 1100 rpm), and the handbrake is applied.
Access diagnostics menu
Access the Vario terminal diagnostics/calibration menu.
Enter calibration code
Enter Calibration Code "9001" (Front EPC calibration / Front power lift calibration).
Sweep potentiometer
Follow the on-screen prompts to sweep the setpoint potentiometer through its full range of motion so the A039 module can relearn the minimum and maximum voltage values.
Save calibration
Save the calibration.
Clear fault codes
Clear the stored fault codes from the tractor's memory (typically done by pressing and holding the designated clear/ESC keys on the terminal).
Replace parts if calibration fails
If the calibration fails to complete, or if the potentiometer has an internal short/open circuit (triggering code 09.1.B3), the potentiometer or the entire multifunction armrest must be replaced, followed by repeating Calibration Code 9001.
Parts you might need
(4)Depth control setpoint potentiometer, front power lift / Armrest Potentiometer
MFA Power 1000E SX
G931970160156fitment for 922-936
Multifunction Arm Rest SX
G931970160118fitment for 922-936
Multi Function SX
G931970160129fitment for 922-936