Fendt 0B.1.B0 – A050 - Basic Control Unit ECU (EXT): A050 - ECU, basic control unit TEACH-IN
Issue description
A CAN communication Teach-In initialisation error where the basic control unit failed to initialize the Teach-In function over the CAN bus network.
Applies to these machines
10 machines- 922 Vario COM III
- 924 Vario COM III
- 927 Vario COM III
- 930 Vario COM III
- 933 Vario COM III
- 936 Vario COM III
- Fendt 900 Vario (COM III)
- 700 SCR
- 800 SCR
- 900 SCR
Check the cause
Check the wiring harness and connectors leading to the A050 Basic Control Unit for corrosion, backed-out pins, or moisture.
Verify the power (+UB) and ground connections at the A050 ECU (e.g., separation points X169 and X1403) to ensure the module is receiving stable voltage during startup.
Scan for other active CAN bus or terminal communication errors (such as 0B.1.11, 0B.1.21, or 0B.1.22) which might indicate a broader network failure rather than an isolated A050 module failure.
Repair steps
EOL Programming
Connect the FENDIAS diagnostic tool and re-flash/re-program the A050 Basic Control Unit.
Sequence Deletion
If the error persists or is accompanied by code 0B.1.B1 (Saving or read-out error in sequence data), delete the existing Teach-In sequences from the terminal and reprogram them.
Module Repair/Replacement
If EOL programming fails and the CAN wiring is intact, the A050 Basic Control Unit has suffered an internal hardware/EEPROM failure and must be repaired or replaced.
Parts you might need
(7)Basic Control Unit (A050)
G737.970.070.035Requires EOL (End-Of-Line) programming via FENDIAS dealer software to match the tractor's specific configuration and chassis number.
Basic Control Unit (A050)
G737.970.070.037Requires EOL (End-Of-Line) programming via FENDIAS dealer software to match the tractor's specific configuration and chassis number.
Basic Control Unit (A050)
G835.970.070.014Requires EOL (End-Of-Line) programming via FENDIAS dealer software to match the tractor's specific configuration and chassis number.
Basic Control Unit (A050)
G931.970.070.032Requires EOL (End-Of-Line) programming via FENDIAS dealer software to match the tractor's specific configuration and chassis number.
Basic Control Unit (A050)
G931.970.070.033Requires EOL (End-Of-Line) programming via FENDIAS dealer software to match the tractor's specific configuration and chassis number.
Basic Control Unit (A050)
G931.970.070.046Requires EOL (End-Of-Line) programming via FENDIAS dealer software to match the tractor's specific configuration and chassis number.
Basic Control Unit (A050)
R917006740Requires EOL (End-Of-Line) programming via FENDIAS dealer software to match the tractor's specific configuration and chassis number.
Get help to fix this fault by requesting a quote