Fendt 1.2.2C – A051 - ECU, Engine Control Unit (EDC 7): K008 - Relay, starter lockout
Issue description
The system has detected a break in the wiring (open circuit) or a short circuit in the starter lockout relay circuit, preventing the engine from starting.
Applies to these machines
15 machines- 411 Vario COM III
- 412 Vario COM III
- 413 Vario COM III
- 414 Vario COM III
- 415 Vario COM III
- 712 Vario COM III
- 714 Vario COM III
- 716 Vario COM III
- 718 Vario COM III
- 818 Vario COM III
- 820 Vario COM III
- Fendt 400 Vario COM III (409, 410, 411, 412)
- Fendt 700 Vario COM III (711, 712, 714, 716)
- Fendt 800 Vario COM III (815, 817, 818, 820 greentec)
- Fendt 900 Vario COM III (916, 920, 924, 926, 930, 933, 936)
Check the cause
Verify Shift Lever Position: Ensure the main shift lever is in neutral, as the starter lockout will naturally prevent starting if the tractor is in gear.
Check Fuses: Inspect the starter relay fuses in the main fuse box (e.g., Fuse holder X050, Fuse 2 - 25 Amps for the glow and starter switch).
Inspect Relay K008: Locate the K008 relay in the cab fuse/relay panel. Check for loose seating, melted pins, or corrosion in the socket.
Wiring Harness Test: Using a multimeter, check for continuity and short-to-ground on the wiring harness between the K008 relay socket and the A051 Engine Control Unit (referencing Fendt wiring diagram Sheet 7).
Repair steps
Disconnect Power
Turn off the ignition and disconnect the battery to prevent electrical spikes during repair.
Access the Relay Panel
Open the main fuse and relay console (typically located on the right-hand side of the cab).
Test/Replace the Relay
Remove the K008 Starter Lockout Relay. Bench-test the relay for internal shorts or an open coil. If it fails, or if you suspect intermittent failure, replace it with a new relay.
Repair Wiring (If Applicable)
If the relay tests fine, trace the wiring back to the EDC using wiring diagram Sheet 7. Repair any broken wires or areas where the insulation has rubbed through and shorted against the chassis.
Reassemble and Reconnect
Seat the new relay firmly into the socket and reconnect the battery.
Clear Codes
Connect the Fendt SERDIA diagnostic tool to the tractor's diagnostic port. Delete the stored error codes (specifically FC:00DF and 00E0, which are associated with this fault).
Verify Repair
Place the tractor in neutral and attempt to start the engine to confirm the starter lockout circuit is functioning correctly.
Parts you might need
(1)12V Multi-Purpose Relay / Starter Lockout Relay (K008)
72435348Standard 12V relay used across the 300, 400, 700, 800, and 900 Vario series.
Get help to fix this fault by requesting a quote