Fendt 1.2.68 – Engine Control Unit (ECU): ECU EMR internal error (ERROR CAN Step 1)
Issue description
Internal processing or memory failure within the engine management system, specifically affecting the CAN bus communication (Step 1).
Applies to these machines
24 machines- 409 Vario
- 410 Vario
- 411 Vario
- 412 Vario
- 711 Vario
- 712 Vario
- 714 Vario
- 715 Vario
- 716 Vario
- 717 Vario
- 718 Vario
- 916 Vario
- 920 Vario
- 924 Vario
- 926 Vario
- 930 Vario
- Fendt Farmer 400
- Fendt Favorit 700
- Fendt Favorit 900
- Fendt 300 Vario
- Fendt 400 Vario
- Fendt 700 Vario
- Fendt 800 Vario
- Fendt 900 Vario
Check the cause
Check the ECU EMR2 module using the FENDIAS or SERDIA (Deutz) diagnostic software
Verify the power supply and CAN bus connections to the EDC/EMR module, as voltage drops or CAN interruptions can sometimes trigger internal processing faults
Refer to Chapter 2000 Reg. B - EMR troubleshooting plan in the Fendt workshop manual for specific pinout testing
Repair steps
Connect Diagnostic Tool
Connect your diagnostic interface to the tractor.
Backup Data
Save the old data record from the ECU EMR2 (Important: save old data record!!).
Flash ECU
Load a new data record (re-flash the firmware/parameters) onto the ECU EMR2.
Cycle Power
Switch the ignition OFF, then back ON.
Evaluate
If the 1.2.68 error reappears after the new data record has been loaded, the internal hardware of the ECU is permanently damaged.
Replace
Replace the ECU EMR2/EDC module.
Parts you might need
(4)Engine Control Unit (ECU) / EDC Module / EMR2 Controller
Generic part name
Engine Control Unit (EDC MS6.4)
0281010317Bosch OEM for Fendt 900 Vario series (e.g., 926, 928, 930)
EDC Engine Control Module
F836200010020OEM for Fendt 828 Vario
Engine Control Unit (EDC17CV54) / EDC17CV52
0281020205Bosch OEM used on newer Fendt Vario models requiring Stage/Tier emissions compliance
Get help to fix this fault by requesting a quote