Fendt 1.2.73 – A051 - ECU, engine control unit (EDC 7): Start of injection period in cylinder 4 outside setpoint range or absent
Issue description
The engine control unit is detecting an anomaly with the fuel injection timing on cylinder 4, meaning the injector is either firing outside of its expected parameters or failing to fire entirely.
Applies to these machines
16 machines- 411 Vario COM III
- 412 Vario COM III
- 413 Vario COM III
- 414 Vario COM III
- 415 Vario COM III
- 712 Vario COM III
- 714 Vario COM III
- 716 Vario COM III
- 718 Vario COM III
- 818 Vario COM III
- 820 Vario COM III
- FENDT 300 Vario (COM III)
- FENDT 400 Vario (COM III)
- FENDT 700 Vario (COM III)
- FENDT 800 Vario (COM III)
- FENDT 900 Vario (COM III)
Check the cause
Use SERDIA diagnostic software to read fault (FC:001B) and attempt to delete the error
Verify the electrical connection between the A051 Engine ECU and the cylinder 4 injector
Test the cylinder 4 injector for mechanical or electrical failure
Repair steps
Connect the SERDIA diagnostic tool
Confirm the presence of fault FC:001B.
Inspect the wiring harness and connectors
Check the wiring harness and connectors between the EDC 7 engine control unit (A051) and the cylinder 4 fuel injector.
Replace the cylinder 4 fuel injector
Replace the injector if the wiring is intact but the injection period remains outside the setpoint range or absent.
Delete the error code
Use the SERDIA tool to delete the error code from the system once the physical repair is complete.
Parts you might need
(3)Fuel Injector (Cylinder 4)
Engine Control Unit (EDC 7) / Module A051
Injector Wiring Harness