Fendt 1.2.83 – ECU EMR2: Reference voltage 1 for Y035 actuator out of allowed range
Issue description
This fault indicates a voltage irregularity in the circuit for the Y035 EMR actuator. The reference voltage has fallen outside the permissible limits, prompting the system to use a substitute value of 5 VDC.
Applies to these machines
24 machines- 409 Vario
- 410 Vario
- 411 Vario
- 412 Vario
- 711 Vario
- 712 Vario
- 714 Vario
- 715 Vario
- 716 Vario
- 717 Vario
- 718 Vario
- 916 Vario
- 920 Vario
- 924 Vario
- 926 Vario
- 930 Vario
- Farmer 400 Vario
- Favorit 700 Vario
- Favorit 900 Vario
- Fendt 300 Vario series
- Fendt 400 Vario series
- Fendt 700 Vario series
- Fendt 800 Vario series
- Fendt 900 Vario series
Check the cause
Monitor the current to see if the error message disappears automatically, which indicates the current has returned to the normal range
Check the voltage supply directly to the ECU EMR2
Inspect the wiring harness running from the Y035 actuator to the ECU for shorts, breaks, or corrosion
Run Deutz SERDIA diagnostics to test the Y035 EMR actuator's feedback and control travel
Repair steps
Test voltage supply
Test the voltage supply to the ECU EMR2 to ensure it is receiving proper power.
Inspect and repair wiring
Inspect and repair any damaged wiring between the Y035 actuator and the ECU.
Cycle ignition
Switch the tractor's ignition OFF, wait a moment, and then switch it back ON.
Replace ECU EMR2
If the error code reappears after the power cycle and wiring checks, replace the ECU EMR2.
Parts you might need
(2)ECU EMR2 (Engine Control Unit)
Primary replacement target if the fault persists after an ignition cycle.
Y035 EMR Actuator
May require replacement if SERDIA diagnostics point to a physical failure of the actuator coil rather than the ECU.
Get help to fix this fault by requesting a quote