Fendt 1.2.85 (DEUTZ EMR) – ECU EMR2: Reference voltage 4 for the Y035 actuator is out of the permissible range
Issue description
The Y035 is the EMR actuator (rotary magnet and position sensor) which is energized via Pulse Width Modulation (PWM) to physically move the engine's control rod based on load requests. When this voltage falls out of the allowed range, the system triggers an error message and defaults to a substitute value of 5 VDC to maintain basic operation. The error message is designed to disappear automatically if the current returns to the normal range.
Applies to these machines
21 machines- 409 Vario
- 410 Vario
- 411 Vario
- 412 Vario
- 711 Vario
- 712 Vario
- 714 Vario
- 715 Vario
- 716 Vario
- 717 Vario
- 718 Vario
- 916 Vario
- 920 Vario
- 924 Vario
- 926 Vario
- 930 Vario
- Fendt 300 Vario (COM III)
- Fendt 400 Vario (COM III)
- Fendt 700 Vario (COM III)
- Fendt 800 Vario (COM III)
- Fendt 900 Vario (COM III)
Check the cause
Verify the main voltage supply to the ECU EMR2
Switch the tractor's ignition OFF, then turn it back ON to see if the error reappears
Check the wiring harness and cable connections between the ECU EMR2 and the Y035 actuator for breaks, shorts, or corrosion
Connect the Deutz SERDIA diagnostic software to test the Y035 actuator's function and read live data
Consult 'Chapter 2000 Reg. B - EMR troubleshooting plan' in the Fendt workshop manual for specific pinout values
Repair steps
Perform diagnostic checks
Perform the diagnostic checks above, paying special attention to the voltage supply to the ECU EMR2.
Cycle ignition
Turn the ignition OFF and then ON.
Verify temporary fluctuation
If the error clears and does not return, it was likely a temporary voltage fluctuation and no further action is required.
Replace the ECU EMR2
If the error reappears immediately after cycling the key and verifying the wiring is intact, replace the ECU EMR2.
Program the new ECU
If the ECU EMR2 is replaced, the new unit will arrive blank. You must use the SERDIA diagnostic tool to back up the engine data set from the old control unit and flash it onto the new one. An unprogrammed ECU will prevent the engine from starting.
Parts you might need
(2)ECU EMR2 (Engine Control Unit)
Deutz EMR2 Controller. Must be programmed via SERDIA with the specific engine data set prior to operation.
Y035 EMR Actuator
Rotary magnet and position sensor / control rod actuator (Generic Deutz part).