1.2.86

Fendt 1.2.86 – ECU EMR2: ECU EMR2 — Temperature in ECU EMR2 too high

Issue description

The internal temperature of the engine control unit has exceeded its safe operating threshold.

Applies to these machines

  • 409 Vario
  • 410 Vario
  • 411 Vario
  • 412 Vario
  • 711 Vario
  • 712 Vario
  • 714 Vario
  • 715 Vario
  • 716 Vario
  • 717 Vario
  • 718 Vario
  • 916 Vario
  • 920 Vario
  • 924 Vario
  • 926 Vario
  • 930 Vario
  • Fendt Farmer 400 Vario
  • Fendt Favorit 700 Vario
  • Fendt Favorit 900 Vario
  • Fendt 300 Vario series
  • Fendt 400 Vario series
  • Fendt 700 Vario series
  • Fendt 800 Vario series
  • Fendt 900 Vario series

Check the cause

  1. Allow the module to cool down so the internal temperature drops back into the normal operating range

  2. Cycle the ignition OFF, wait a moment, and then switch it back ON

  3. Check SERDIA Diagnostics and refer to Chapter 2000 Reg. B - EMR troubleshooting plan if further diagnosis is needed

Repair steps

  1. Ensure the tractor has cooled down and the ambient temperature around the ECU is normal.

  2. Switch the ignition OFF, then ON.

  3. If the error reappears despite the temperature being in the normal range, the internal temperature sensor or the board itself has failed.

  4. Replace the ECU EMR2.

    When replacing an EMR2 ECU, the old data record must be saved and flashed/loaded onto the new control unit using the SERDIA diagnostic tool.