1.2.92

Fendt 1.2.92 – EDC Control Module (A021) / Pump Control Unit (A020): Engine stop via "Injected volume = 0" faulty.

Issue description

This fault indicates a communication or execution failure between the engine control unit and the injection pump during the engine shutdown sequence. Normally, the Engine Control Unit (A021) sends a signal via the EDC CAN-BUS to the Pump Control Unit (A020) commanding the "Injected volume set at 0" to shut down the engine. The system will force restricted power (limp mode) or the engine may stop unexpectedly.

Applies to these machines

  • 409 Vario
  • 410 Vario
  • 411 Vario
  • 412 Vario
  • 711 Vario
  • 712 Vario
  • 714 Vario
  • 715 Vario
  • 716 Vario
  • 717 Vario
  • 718 Vario
  • 916 Vario
  • 920 Vario
  • 924 Vario
  • 926 Vario
  • 930 Vario
  • 815 Vario
  • 817 Vario
  • 818 Vario
  • 930 Vario (Chassis number 23/3001 and up)

Check the cause

  1. Verify the EDC CAN-BUS wiring between the Engine Control Module (A021) and the Pump Control Unit (A020) for discontinuities, corrosion, or short circuits

  2. Check Connector X047 (Pins 24 / 27) on the Engine Control Unit A021, which sends the 'Injected volume set at 0' signal

  3. Verify the supply voltage (UB 15) from the ignition lock (S002) to the Engine Control module (A021) at Connector X048

  4. Check for accompanying CAN-BUS timeout codes (e.g., 1.2.B1) to isolate wiring/communication breaks from mechanical pump failures

Repair steps

  1. Inspect Wiring

    Trace the CAN-BUS harness between the EDC (A021) and the Injection Pump (A020). Repair any damaged wires or clean corroded connector pins.

  2. Test the Shutdown Signal

    Using a diagnostic adapter box and multimeter/oscilloscope, verify if the A021 module is actually outputting the shutdown signal when the ignition is turned off.

  3. Component Replacement

    If the wiring is intact and the EDC module is sending the signal but the pump does not respond, replace or rebuild the VP44 Electronic Injection Pump (A020). If the EDC module fails to send the signal, replace the EDC Control Module (A021).

  4. Reprogramming

    If the EDC Control Module (A021) is replaced, perform EOL (End of Line) reprogramming using FENDIAS / Serdia diagnostic software to pair the new module with the tractor's CAN-BUS network.

Parts you might need

(2)
  • Electronic Injection Pump (Bosch VP44) - Component A020

    Fitment: Fendt 400/700/800/900 Vario series with EDC. Often requires specialized diesel shop calibration if the pump control unit is replaced.

  • EDC Engine Control Module - Component A021

    Fitment: Fendt Vario series. Requires EOL programming upon installation.

Get help to fix this fault by requesting a quote

Browse other Fendt codes