1.2.A2

Fendt 1.2.A2 – EDC Control Module (A021): K021 - Relay 'solenoid valve shut-off' (EDC) — Engine stop via relay K021

Issue description

Relay time delay error where the engine stop via the pump relay (K021) is not possible. The system detects that the relay is not functioning correctly to shut off the solenoid valve. The tractor will enter a restricted operating mode with full power fuel flow reduced by 25-40% and maximum engine speed reduced to 1900 RPM.

Applies to these machines

  • 409 Vario
  • 410 Vario
  • 411 Vario
  • 412 Vario
  • 711 Vario
  • 712 Vario
  • 714 Vario
  • 715 Vario
  • 716 Vario
  • 717 Vario
  • 718 Vario
  • 916 Vario
  • 920 Vario
  • 924 Vario
  • 926 Vario
  • 930 Vario
  • Farmer 409
  • Farmer 410
  • Farmer 411
  • Farmer 412
  • Favorit 711
  • Favorit 712
  • Favorit 714
  • Favorit 716
  • Favorit 916
  • Favorit 920
  • Favorit 924
  • Favorit 926
  • Favorit 930
  • 815 Vario
  • 817 Vario
  • 818 Vario

Check the cause

  1. Check the bevel pinion speed sensor signal (if speed displays 0 km/h while moving and ignition is OFF, a false delay time error occurs).

  2. Record the failure and ambient parameters using the FENDIAS diagnostic program.

  3. Clear the failure code memory using the EDC Diagnostic Program or FENDIAS.

  4. Run the tractor and retest with the diagnostic program to verify if the engine speed drops below 300 RPM within 10 seconds.

Repair steps

  1. Analyze and delete failure codes

    Analyze and delete the failure codes. In the case of multiple codes, first perform the test procedures that do not request the replacement of the Control Module or the pump.

  2. Replace the EDC Control Module

    If the 1.2.A2 failure persists after clearing the memory and retesting, replace the EDC Control Module (A021).

  3. Record parameters and delete failure code memory

    After replacing the EDC Control Module, record parameters and delete the failure code memory again with FENDIAS.

  4. Replace the Injection Pump

    Check the system again. If the failure still persists, replace the Injection Pump (VP44 / A020).

Parts you might need

(3)
  • Relay K021 (Engine Stop Solenoid Valve Relay / Cutout Solenoid Relay)

    Generic standard automotive/tractor relay located in the right rear of the cab (under the cover).

  • EDC Control Module (A021)

    OEM Fendt Engine Control Unit (part numbers vary heavily by specific engine/tractor model and require EOL programming upon installation).

  • Injection Pump (A020)

    F926202710740, FCU926202520000, 0470506045, 0470506047, 0470506042

    Bosch VP44 Distributor Injection Pump.

Get help to fix this fault by requesting a quote