Fendt 1.2.C5 – Engine Control Module (EDC): Fault in engine stop via engine stop solenoid valve
Issue description
The system has detected a failure during the engine shutdown process that is managed by the stop solenoid valve. When this code is active, the tractor will enter a restricted operating mode, resulting in reduced engine speed and reduced engine power.
Applies to these machines
37 machines- 409 Vario
- 410 Vario
- 411 Vario
- 412 Vario
- 711 Vario
- 712 Vario
- 714 Vario
- 715 Vario
- 716 Vario
- 717 Vario
- 718 Vario
- 916 Vario
- 920 Vario
- 924 Vario
- 926 Vario
- 930 Vario
- Fendt 300 Vario series
- Fendt 400 Vario series
- 409
- 410
- 411
- 412
- Fendt 700 Vario series
- 711
- 712
- 714
- 716
- Fendt 800 Vario series
- 815
- 817
- 818
- Fendt 900 Vario / Favorit 900 series
- 916
- 920
- 924
- 926
- 930
Check the cause
Review the 'EDC Control' electric diagram to trace the wiring between the EDC Control Module (A021), the Pump Control Unit (A020), and the stop solenoid valve
Inspect the wiring and connectors for discontinuities, loose connections, or short circuits in the harness leading to the engine stop solenoid valve
Connect the FENDIAS diagnostic tool to record the failure and ambient parameters
Run Test 30 (Relay Delay Time: Engine Stop with MAB-Signal) to evaluate the engine stop circuit
Repair steps
Preparation
Turn the ignition 'OFF' and connect the adaptor box with adapting connectors if performing pin-out tests on the EDC module.
Inspect the Solenoid
Locate the engine stop solenoid valve on the injection pump assembly. Inspect it for physical damage, corrosion, or fuel leaks.
Test/Replace the Solenoid
If the wiring (checked in the diagnostic phase) is intact but the solenoid fails to actuate or shows out-of-spec resistance, remove the faulty engine stop solenoid valve and install a replacement.
Clear Codes
Use the FENDIAS diagnostic software to delete the failure code memory.
Verification
Start the engine, perform a normal shutdown, and check again with FENDIAS to ensure the fault code does not return.
Parts you might need
(6)Engine Stop Solenoid Valve / Fuel Shut Down Stop Solenoid
Generic Name
Engine Stop Solenoid Valve
F716201260010Fitment note: specifically listed for Fendt Favorit 716
24V Fuel Stop Solenoid Valve
F816201710020Fitment note: 24V systems
Solenoid Valve
F149200710260Fitment note: Fendt 208, 209, GT380
Stop Solenoid Valve
380151643Adaptable aftermarket stop solenoid valve compatible with various Fendt applications
Stop Solenoid Valve
2848A279Adaptable aftermarket stop solenoid valve compatible with various Fendt applications
Get help to fix this fault by requesting a quote