10.1.32

Fendt 10.1.32 – A038 - ECU, Central Electrical System: M016 - Servomotor, bottom air valve

Issue description

Function non-operable. This code indicates a failure in the HVAC system's bottom air valve servomotor (actuator). The system has detected that the motor responsible for opening and closing the bottom air flap is not functioning, which will prevent proper air distribution in the cab.

Applies to these machines

  • 922 Vario COM III
  • 924 Vario COM III
  • 927 Vario COM III
  • 930 Vario COM III
  • 933 Vario COM III
  • 936 Vario COM III
  • Fendt 300 Vario (COM III)
  • Fendt 400 Vario (COM III)
  • Fendt 500 Vario (S4 Series)
  • Fendt 700 Vario (COM III, SCR, S4 Series)
  • Fendt 800 Vario (COM III, S4 Series)
  • Fendt 900 Vario (COM III, SCR, S4 Series)

Check the cause

  1. Measure the resistance of the M016 servomotor across the pins at the X1547 connector (should be approximately 49.1 ohms)

  2. Command the vent flap to open (F20 on the diagnostic terminal) and measure Pin 18 at the X1547 connector; it should receive 12 VDC

  3. Command the vent flap to close (F15 on the diagnostic terminal) and measure Pin 20 at the X1547 connector; it should receive 12 VDC

  4. Check the current draw while the flap is actuating using a multimeter; it should pull approximately 16 mADC

Repair steps

  1. Locate the Component

    The M016 servomotor and its X1547 connector are located inside the cab, specifically inside the air box situated just before the steering column.

  2. Access the Air Box

    Remove the exterior panels/trim surrounding the steering column to access the HVAC air box.

  3. Remove the Cover

    Take off the air box cover to expose the flap servomotors.

  4. Disconnect

    Unplug the X1547 electrical separation point from the M016 servomotor.

  5. Replace

    Unbolt the faulty servomotor from the blend door linkage and install the new unit.

  6. Reassemble

    Reconnect the X1547 plug, reinstall the air box cover, and secure the steering column trim.

  7. Clear Codes

    Turn the ignition ON, access the Varioterminal diagnostics menu, and clear the stored 10.1.32 fault code. Test the HVAC system to ensure air routes correctly to the bottom vents.

Parts you might need

(1)
  • Servomotor, bottom air valve (HVAC blend door actuator / flap motor)

    Specific OEM part numbers are not published; order via dealer using generic name and tractor chassis number.