Fendt 10.1.38 – A038 - ECU, central electrical system: Function non-operable in A038 - ECU, central electrical system
Issue description
Indicates a 'Function non-operable' state within the A038 - ECU, central electrical system. The primary consequence is that the tractor's air conditioning system is forced to run in 'emergency mode'. This code is also linked to a bus fault or communication failure with the central electrical system.
Applies to these machines
13 machines- 922 Vario COM III
- 924 Vario COM III
- 927 Vario COM III
- 930 Vario COM III
- 933 Vario COM III
- 936 Vario COM III
- 300 Vario (COM III)
- 400 Vario (COM III)
- 700 Vario (COM III)
- 800 Vario (COM III)
- 900 Vario (COM III)
- 919 Vario COM III
- 925 Vario COM III
Check the cause
Inspect the A013 PCB microfuses for a supply voltage drop (e.g., 8.5V supply fault) which can cause modules to drop offline.
Use the official Fendt adapter box to test the A038 central electrical system ECU directly.
Measure the control bus terminating resistance with the ignition OFF (should measure approximately 60 ohms, representing two 120-ohm resistors in parallel).
Inspect the main harness connections to the A038 ECU (separation points/connectors X454 and X455) for corrosion, backed-out pins, or moisture intrusion.
Repair steps
Power Down
Disconnect the tractor's battery to prevent electrical arcing or further module damage.
Access the Module
Locate the A038 Central Electrical System ECU (typically located in the right-hand side control console/dashboard area or main electrical distribution panel).
Inspect and Clean
Disconnect the X454 and X455 connectors. Clean the contacts with electronic cleaner. If wiring damage is found, repair the harness.
Module Replacement
If the wiring and bus resistance are intact but the module remains non-operable, the A038 ECU has likely suffered an internal hardware failure and must be replaced (it is non-repairable).
EOL Programming
Install the new A038 ECU. Connect the tractor to the FENDIAS diagnostic software and perform EOL (End of Line) programming to configure the new module to the tractor's CAN bus network.
Clear and Test
Clear the stored 10.1.38 fault code and test the air conditioning system to verify it has exited emergency mode and resumed normal operation.
Parts you might need
(4)Central Electrical System ECU (Control Module A038)
G931901020235Genuine Fendt / AGCO part. Ensure the part number matches your specific chassis serial number break.
Central Electrical System ECU (Control Module A038)
G931901020233Superseded by G931901020235
Central Electrical System ECU (Control Module A038)
G931901020234Superseded by G931901020235
OEM Adapter cable for A038 testing
X899980304203
Get help to fix this fault by requesting a quote